Show simple item record

dc.contributor.advisorIan A. Waitz.en_US
dc.contributor.authorKirk, Daniel Robert, 1975-en_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Aeronautics and Astronautics.en_US
dc.date.accessioned2005-09-06T21:28:19Z
dc.date.available2005-09-06T21:28:19Z
dc.date.issued2003en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/27047
dc.descriptionThesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Aeronautics and Astronautics, June 2003.en_US
dc.description"August 2002."en_US
dc.descriptionIncludes bibliographical references (p. 73-77).en_US
dc.description.abstractAs commercial and military aircraft engines approach higher total temperatures and increasing overall fuel-to-air ratios, there exists a potential for significant heat release to occur in the turbine if energetic species emitted from the combustor are further oxidized during interaction with film-cooling flows. Currently there is little basis for understanding the effects on aero-performance and durability due to such secondary reactions. To study surface heat flux augmentation due to near-wall reactions, a shock tube experiment was employed to generate short duration, high temperature (1000-2800 K) and pressure (6 atm.) fuel-rich flows over a film-cooled flat plate. The relative increase in surface heat flux due to near-wall reactions was investigated over a range of fuel levels, mass blowing ratios (0.5-2.0), and Damkohler numbers (ratio of flow to chemical time scales) from near zero to 30. It was shown that significant increases in surface heat flux can be produced due to chemical reactions in the film-cooling layer. Under some conditions, the heat flux exceeded that obtained when no film-cooling layer was present on the surface. A numerical tool was developed and showed good agreement with the experimental results for predicting changes in surface heat flux and film effectiveness in the presence of local reactions. Off-surface effects and changes in convective heat transfer coefficient were also evaluated. Realistic turbine and cooling flows were examined to ascertain the robustness of various cooling configurations to near-wall reactions. The result of this work is a set of tools based on a group of parameters that can be used to assess changes in heat load due to near-wall reactions. The non-dimensional parameters are the Damkohleren_US
dc.description.abstract(cont.) number (Da), mass and momentum blowing ratios (B and I), freestream energetic heat release potential (H*), and scaled heat flux ratio (Qs). The scaled heat flux ratio always increases with Damk6hler number and depends on the structure of the cooling jet, but is not a function of the freestream fuel energy content.en_US
dc.description.statementofresponsibilityby Daniel Robert Kirk.en_US
dc.format.extent99 p.en_US
dc.format.extent5740131 bytes
dc.format.extent5751501 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.language.isoen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582
dc.subjectAeronautics and Astronautics.en_US
dc.titleNear-wall reaction effects on film-cooled surface heat transferen_US
dc.typeThesisen_US
dc.description.degreePh.D.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Aeronautics and Astronautics
dc.identifier.oclc56795433en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record