MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Graduate Theses
  • View Item
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Graduate Theses
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Transcutaneous measurement of glucose using Raman spectroscopy

Author(s)
Oh, Jeankun, 1968-
Thumbnail
DownloadFull printable version (7.743Mb)
Other Contributors
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Advisor
Michael S. Feld.
Terms of use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582
Metadata
Show full item record
Abstract
Transcutaneous glucose measurement would provide the ability to obtain frequent measurements without the pain and risk of infection associated with obtaining a blood sample and eliminates the need for reagents. Because of these potential benefits, a large effort is being made within the academic and industrial research communities to develop alternative rapid and easily manageable analysis methods, including transcutaneous methods. Several optical techniques have been proposed and investigated widely to replace the traditional method. Transcutaneous measurement would be of particular benefit to the millions of people with diabetes who should monitor glucose levels multiple times per day and today depend on the finger pricking devices. We have used the advantages provided by NIR Raman spectroscopy, i.e. sharp and distinct spectral features combined with a large probe volume, in order to simultaneously quantify multiple analytes (glucose, urea, cholesterol, triglycerides, total protein, albumin, hemoglobin, hematocrit (hct)) in serum and whole blood samples. Based on the successful measurements, we have moved toward transcutaneous measurements of glucose from 16 healthy human subjects as the first target of blood analytes. RMSEP of 13.17 mg/dL and r² values of 0.79 show promise that the Raman spectroscopy can be developed to achieve clinical accuracy requirements. Furthermore, the fact that glucose features could be recognized in the calibration spectra from measurements of volunteers whose glucose levels changed in a relatively large range, provides evidence that the calibration is based upon glucose.
Description
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2004.
 
Includes bibliographical references (p. 86-88).
 
Date issued
2004
URI
http://hdl.handle.net/1721.1/27121
Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Publisher
Massachusetts Institute of Technology
Keywords
Mechanical Engineering.

Collections
  • Graduate Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.