Show simple item record

dc.contributor.advisorRoger D. Kamm.en_US
dc.contributor.authorXiao, Xinshuen_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Mechanical Engineering.en_US
dc.date.accessioned2005-09-26T19:15:40Z
dc.date.available2005-09-26T19:15:40Z
dc.date.copyright2000en_US
dc.date.issued2000en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/28230
dc.descriptionIncludes bibliographical references.en_US
dc.descriptionThesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2000.en_US
dc.description.abstractCardiovascular health is currently assessed by a collection of hemodynamic parameters many of which can only be measured by invasive methods often requiring hospitalization. A non-invasive approach of evaluating some of these parameters, such as systemic vascular resistance (SVR), maximum left ventricular elasticity (ELV), end diastolic volume (VED), cardiac output and others, has been established. The method has three components: (1) a distributed model of the human cardiovascular system (Ozawa) to generate a solution library that spans the anticipated range of parameter values, (2) a method for establishing the multi-dimensional relationship between features computed from the arterial blood pressure and/or flow traces (e.g., mean arterial pressure, pulse amplitude, mean flow velocity) and the critical hemodynamic parameters, and (3) a parameter estimation method that provides the best fit between measured and computed data. Sensitivity analyses are used to determine the critical parameters that must be allowed to vary, and those that can be assumed to be constant in the model. Given the brachial pressure and velocity profiles (which can be measured non-invasively), this method can estimate SVR with an error of less than 3%, and ELv and VED with less than 10% errors. Measurements on healthy volunteers and patients were conducted in Brigham and Women's Hospital, Boston, MA. Carotid, brachial and radial pressures were measured by tonometry and velocities at corresponding locations were measured by ultrasound. Reasonable agreement is found between the measured pressure and velocity curves and the reconstructed ones. Invasive measurements of hemodynamic parameters are available for two of the patients, which are compared to predictions to evaluate the performance of parameter estimation routines.en_US
dc.description.statementofresponsibilityby Xinshu Xiao.en_US
dc.format.extent129 leavesen_US
dc.format.extent6412357 bytes
dc.format.extent6428856 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.language.isoen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582
dc.subjectMechanical Engineering.en_US
dc.titleNoninvasive assessment of cardiovascular healthen_US
dc.typeThesisen_US
dc.description.degreeS.M.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineering
dc.identifier.oclc48379143en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record