Show simple item record

dc.contributor.advisorDennis M. Freeman.en_US
dc.contributor.authorGu, Jianwen Wendy, 1981-en_US
dc.contributor.otherMassachusetts Institute of Technology. Biological Engineering Division.en_US
dc.date.accessioned2005-09-27T16:50:16Z
dc.date.available2005-09-27T16:50:16Z
dc.date.copyright2004en_US
dc.date.issued2004en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/28530
dc.descriptionThesis (M. Eng.)--Massachusetts Institute of Technology, Biological Engineering Division, 2004.en_US
dc.descriptionIncludes bibliographical references (leaf 39).en_US
dc.description.abstractDynamic material properties of the isolated mouse tectorial membrane (TM) were quantified by applying sinusoidal shearing forces to the TM with a microfabricated probe (contact area 30 x 30 [micro]m²). Forces in the range 30-300 nN with frequency in the range 10-9000 Hz were applied tangentially to the surfaces of four TM specimens. We found that TM displacement was linear with respect to force. The TM exhibited both elastic and viscous characteristics, with the elastic behavior being more prominent. The elastic and viscous components of TM impedance remained proportional through two decades of frequency. The radial impedance was approximately three times larger than the longitudinal impedance. The point stiffness of the TM increased with frequency when radial forces were applied but showed no trend with frequency for longitudinal forces. Displacement of surrounding tissue decreased as distance from the probe increased. Space constants were on the order of tens of micrometers. These results represent the most detailed shear measurements to date of the isolated TM and are consistent with those obtained using the magnetic bead method [AF00].en_US
dc.description.statementofresponsibilityby Jianwen Wendy Gu.en_US
dc.format.extent39 leavesen_US
dc.format.extent1343842 bytes
dc.format.extent1346000 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.language.isoen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsMIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582
dc.subjectBiological Engineering Division.en_US
dc.titleMeasuring mechanical properties of the tectorial membrane with a microfabricated probeen_US
dc.title.alternativeShear measurements of mouse tectorial membrane using microelectromechanical systems probeen_US
dc.typeThesisen_US
dc.description.degreeM.Eng.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Biological Engineering
dc.identifier.oclc57364218en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record