Show simple item record

dc.contributor.advisorWilliam M. Wells, III.en_US
dc.contributor.authorKim, Elizabeth S. (Elizabeth Seon-wha), 1979-en_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.en_US
dc.date.accessioned2005-09-27T17:47:22Z
dc.date.available2005-09-27T17:47:22Z
dc.date.copyright2004en_US
dc.date.issued2004en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/28690
dc.descriptionThesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2004.en_US
dc.descriptionIncludes bibliographical references (p. 73-76).en_US
dc.description.abstractProstate cancer's high incidence and high survivability motivate its treatment using tightly focused radiation therapy. Brachytherapy treatment, the implantation of radioactive seeds into the prostate, is increasing in popularity, spurred by advances in medical imaging techniques for prostate visualization. Successful brachytherapy requires precise positioning of implant seeds within the pelvic anatomy. Following implantation, precise localization of individual seeds is required to evaluate treatment, but this remains an open challenge. This thesis addresses the seed localization problem with contributions for improving seed-based registration of MR and CT post-implant images. A model for non-rigid, affine prostate motion is presented and demonstrated to improve on current techniques of rigid registration. Also, an evaluation of the benefit of using multiple, rather than a few, seeds is presented, along with a scheme for validating registrations using manually detected seeds in MR and CT volumes. Finally, a scheme for automatic seed-based MR and CT registration by aligning all seeds is suggested, with supporting algorithms for CT seed-finding and unmatched feature registration. A call for an MR seed-finder is issued, for this is the final component needed to achieve automatic and complete seed-based MR and CT registration.en_US
dc.description.statementofresponsibilityby Elizabeth S. Kim.en_US
dc.format.extent76 p.en_US
dc.format.extent4267003 bytes
dc.format.extent4274963 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.language.isoen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582
dc.subjectElectrical Engineering and Computer Science.en_US
dc.titleImproved seed-based MR and CT image registration for prostate brachytherapyen_US
dc.title.alternativeImproved seed-based magnetic resonance and computer tomography image registration for prostate brachytherapyen_US
dc.typeThesisen_US
dc.description.degreeM.Eng.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
dc.identifier.oclc59007682en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record