Show simple item record

dc.contributor.advisorDavid G. Corey.en_US
dc.contributor.authorSun, Phillip Zheen_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Nuclear Engineering.en_US
dc.date.accessioned2006-03-24T18:10:12Z
dc.date.available2006-03-24T18:10:12Z
dc.date.copyright2003en_US
dc.date.issued2003en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/29996
dc.descriptionThesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Nuclear Engineering, 2003.en_US
dc.descriptionIncludes bibliographical references.en_US
dc.description.abstractThe goal of the work described in this thesis is to develop the methodology and instrumentation for studying neuron physiology and activation in vivo at near cellular resolution. Using biocompatible crosslinked Hemoglobin (xHb) as a contrast agent, we demonstrated partial local oxygen pressure (pO₂) monitoring in vivo with a home-built high resolution microscopy imaging probe. It is one of the most stable microimaging system designed and fully equipped for microscopic fMRI study. This work is an advancement of using MRI to study fundamental neuron science and cell signal pathways in vivo. NMR Microscopy of pancreatic islet of NOD-SCID mice in vitro has shown the feasibility of tracking T-lymphocytes infiltration into islets before the onset of any diabetes symptoms using contrast agents CLIO-Tat. Application of this to in vivo study will not only advance our understanding of the progression IDDM but also help monitor the treatment and prognosis of IDDM patients. Throughout the high resolution imaging studies at high field (14.1 T), a new gradient sequence was developed to suppress the distortion due to the internal fields. This sequence can faithfully measure the displacement propagator in q-space imaging, and provide the proper displacement contrast in k-space imaging. The constant time imaging technique has been used to image a phantom model of a vascular system. It is made up of two glass tubes, filled with solutions of D[sub]y - DTPA and C[sub]uSO₄ respectively and the field mapping showed significant internal field introduced by their susceptibility difference. The new sequence may find applications in clinical Diffusion Tensor Imaging (DTI) and Diffusion Weighted Imaging (DWI).en_US
dc.description.statementofresponsibilityby Philip Zhe Sun.en_US
dc.format.extent131 p.en_US
dc.format.extent5723853 bytes
dc.format.extent5723662 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582
dc.subjectNuclear Engineering.en_US
dc.titleNuclear magnetic resonance microscopy and diffusionen_US
dc.title.alternativeNMR microscopy and diffusionen_US
dc.typeThesisen_US
dc.description.degreePh.D.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Nuclear Engineeringen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Nuclear Science and Engineering
dc.identifier.oclc55000216en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record