Show simple item record

dc.contributor.advisorDava J. Newman.en_US
dc.contributor.authorBethke, Kristen (Kristen Ann)en_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Aeronautics and Astronautics.en_US
dc.date.accessioned2006-03-29T18:45:00Z
dc.date.available2006-03-29T18:45:00Z
dc.date.copyright2005en_US
dc.date.issued2005en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/32443
dc.descriptionThesis (S.M.)--Massachusetts Institute of Technology, Dept. of Aeronautics and Astronautics, 2005.en_US
dc.descriptionIncludes bibliographical references.en_US
dc.description.abstractThe primary aim of this thesis is to advance the theory of advanced locomotion mechanical counter pressure (MCP) spacesuits by studying the changes in the human body shape during joint motion. Two experiments take advantage of three-dimensional laser scan technology to measure the shape changes of the human body. The first experiment is an analysis of the surface area and volume of the thigh, knee, calf, and entire leg during knee flexion. The second experiment is an analysis of the full-field strain on the skin surface of the leg during knee flexion. A repeatable and quantitative technique for mapping the leg skin strain field is developed. The results of the algorithm indicate the magnitude of strain over the entire surface of the leg, as well as the direction of minimum leg skin stretching during knee flexion. For 88% of the leg surface, knee flexion causes skin strain between -0.3 and 0.3 (less than 30% contraction or extension). However, just below the patella, longitudinal strain is as high as 0.7, and at the knee hollow, it is as low as -0.6. Circumferential strain values are as high as 1.0 and 0.5 just below the patella and over the calf muscle, respectively, and along the anterior surface of the lower leg, they are as low as -0.7. The leg area, volume, and skin strain results lead to quantitative design requirements for highly mobile second skin spacesuits, and they inspire two prototype MCP leg sleeves: a hybrid urethane-foam bladder garment and a skintight nylon fiber lines of non-extension garment. These two prototypes are constructed and tested for mobility and skin surface pressure. Pressurization of the hybrid foam prototype inhibits leg mobility.en_US
dc.description.abstract(cont.) However, the nylon lines of non-extension prototype shows promise as an advanced locomotion spacesuit design concept. During pressurization to leg surface pressure of 7.5 kPa (56 mmHg, 1.1 psi), the prototype preserves easy mobility to 90 degrees of knee joint flexion. Recommendations are made for improving its pressure production performance to the desired 30 kPa (222 mmHg, 4.3 psi) level.en_US
dc.description.statementofresponsibilityby Kristen Bethke.en_US
dc.format.extent148 p.en_US
dc.format.extent14339804 bytes
dc.format.extent14347842 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582
dc.subjectAeronautics and Astronautics.en_US
dc.titleThe second skin approach : skin strain field analysis and mechanical counter pressure prototyping for advanced spacesuit designen_US
dc.title.alternativeSkin strain field analysis and mechanical counter pressure prototyping for advanced spacesuit designen_US
dc.typeThesisen_US
dc.description.degreeS.M.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Aeronautics and Astronautics
dc.identifier.oclc61719483en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record