Show simple item record

dc.contributor.advisorKlavs F. Jensen.en_US
dc.contributor.authorGriswold, Aaron A. (Aaron Alexander), 1981-en_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Mechanical Engineering.en_US
dc.date.accessioned2006-05-15T20:31:56Z
dc.date.available2006-05-15T20:31:56Z
dc.date.copyright2004en_US
dc.date.issued2004en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/32812
dc.descriptionThesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2004.en_US
dc.descriptionIncludes bibliographical references (leaf 18).en_US
dc.description.abstractA miniaturized bioreactor with a volume on the order of 100 [micro]l has been built with the aim of increasing the efficiency of the screening process for various microbial cultures. Unlike larger reactors currently in use, the current miniaturized design lacks a method of pH control. Without pH control, cell growth can be hindered or even stopped altogether when the growing medium becomes too acidic. Using technology already in place to optically measure the pH inside the reactor in conjunction with a valve and a base-filled reservoir, a simple closed-loop (feedback) control system has been developed. The volume of base injected into the reactor must be minimized because the reactor itself is so small. Data is recorded and control signals are outputted by a computer running LabView software. While the control system developed in this thesis shows promise, further development is needed before it can be put to good use.en_US
dc.description.statementofresponsibilityby Aaron A. Griswold.en_US
dc.format.extent18 leavesen_US
dc.format.extent944171 bytes
dc.format.extent941817 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582
dc.subjectMechanical Engineering.en_US
dc.titlepH control in a miniaturized bioreactoren_US
dc.title.alternativeHydrogen-ion concentration control in a miniaturized bioreactoren_US
dc.typeThesisen_US
dc.description.degreeS.B.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineering
dc.identifier.oclc57588533en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record