Show simple item record

dc.contributor.advisorUlrich J. Becker.en_US
dc.contributor.authorTamm, Brian Paulen_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Physics.en_US
dc.date.accessioned2006-05-15T20:38:18Z
dc.date.available2006-05-15T20:38:18Z
dc.date.copyright2005en_US
dc.date.issued2005en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/32905
dc.descriptionThesis (S.B.)--Massachusetts Institute of Technology, Dept. of Physics, 2005.en_US
dc.descriptionIncludes bibliographical references (p. 85-87).en_US
dc.description.abstractThe gas electron multiplier (GEM) is a novel charge amplification element for use in gaseous particle detectors. Because of their high gain ([approx.] 10⁵ when cascaded) and ability to withstand harsh radiation conditions, GEMs have been selected for use in the time projection chambers of the latest high-energy experiments, including COMPASS, STAR, and the planned ILC. Foil quality has been found to be critical for optimal GEM performance. If an irregularity in just one of the roughly 600, 000 amplification holes of a 10 x 10 cm GEM induces a spark discharge, the entire GEM is useless. Computer simulations have also shown that amplification behavior is strongly dependent on hole diameter and shape. To improve foil quality control, an automated scanner has been constructed to optically examine every hole in a GEM. The machine can measure each hole's outer copper diameter and inner Kapton diameter and locate and geometrically classify any foil imperfections. The scanner has been used to characterize GEMs recently manufactured by Tech-Etch. These scans indicate a general absence of etching defects, but measured diameter inhomogeneity may result in gain variations as large as i20% over the active foil area.en_US
dc.description.statementofresponsibilityby Brian Paul Tamm.en_US
dc.format.extent87 p.en_US
dc.format.extent4390260 bytes
dc.format.extent4394385 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582
dc.subjectPhysics.en_US
dc.titleGas electron multipliers and a scanner for automated quality controlen_US
dc.title.alternativeGEMs and a scanner for automated quality controlen_US
dc.typeThesisen_US
dc.description.degreeS.B.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Physics
dc.identifier.oclc62626635en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record