Show simple item record

dc.contributor.advisorIan H. Hutchinson.en_US
dc.contributor.authorYoungblood, Brian Joaquinen_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Nuclear Engineering.en_US
dc.date.accessioned2006-07-31T15:18:24Z
dc.date.available2006-07-31T15:18:24Z
dc.date.copyright2004en_US
dc.date.issued2004en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/33629
dc.descriptionThesis (S.M.)--Massachusetts Institute of Technology, Dept. of Nuclear Engineering, 2004.en_US
dc.descriptionIncludes bibliographical references (leaves 75-76).en_US
dc.description.abstractBolometry is a diagnostic technique common to most tokamak fusion experiments. Bolometers are so widespread because they provide an important measure of the energy lost from confined plasmas as radiation, as well as being relatively simple and resilient in their construction. Here the bolometric diagnostics of the Alcator C-mod tokamak, their function, limitations, and the details of their calibration, operation, and maintenance are covered. In addition, the results of a variety of investigations into the behavior of C-mod plasmas as observed by bolometers are presented and discussed. The measurements dealt with are either measurements of total power radiated by the plasma or measurements of radial emissivity profiles. Measurements of the first kind are suitable for studying the effects of factors like net input power while measurements of the second kind are useful for studying the effects of factors like local temperature profiles and plasma composition.en_US
dc.description.statementofresponsibilityby Brian Joaquin Youngblood.en_US
dc.format.extent76 leavesen_US
dc.format.extent3093476 bytes
dc.format.extent3096585 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582
dc.subjectNuclear Engineering.en_US
dc.titleBolometer diagnostics on Alcator C-moden_US
dc.typeThesisen_US
dc.description.degreeS.M.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Nuclear Engineeringen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Nuclear Science and Engineering
dc.identifier.oclc64392602en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record