Show simple item record

dc.contributor.advisorJongyoon Han and Peter So.en_US
dc.contributor.authorMao, Panen_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Mechanical Engineering.en_US
dc.date.accessioned2006-09-28T15:12:21Z
dc.date.available2006-09-28T15:12:21Z
dc.date.copyright2005en_US
dc.date.issued2005en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/34152
dc.descriptionThesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2005.en_US
dc.descriptionIncludes bibliographical references (leaves 87-94).en_US
dc.description.abstractThis thesis has characterized the applicability and limitation of PDMS micromolding and the substrate bonding techniques including both anodic (Si-glass) and thermal fusion (glass-glass) bonding, in fabricating sub-100-nm thick nanofluidic channels, which will be used for a controlled experimental study of molecular and fluidic transport in confined space. It is found that the fabrication of nanofluidic channels using PDMS substrate is generally limited to the thickness of -100 nm because of the softness of the materials. Also, the gas permeability of PDMS poses a significant challenge in the operation of the nanofluidic devices. We demonstrate that nanofluidic channels, as thin as 20 nm with high aspect ratio (more than 250:1, width to depth) on silicon substrate and 25 nm with aspect ratio of 2000 on glass substrate can be achieved with anodic bonding technique and direct glass-glass bonding technique, respectively. Scanning electron microscopy (SEM) measurement is used to prove that the channels are of good uniformity and there is no significant change of the depth of nanofluidic channels due to anodic bonding process and glass-glass bonding process.en_US
dc.description.abstract(cont.) In addition, we have demonstrated massively-parallel vertical nanofluidic filters, with fluidic conductance as large as standard microfluidic channels, by using a combination of deep reactive ion etching (DRIE) and anisotropic KOH etching followed by an oxidation step. The lateral nanofilter array device achieved separation of the mixture of X-DNA and Hind III digest of lambda DNA in half an hour by the mechanism of entropic trapping. The fabrication strategy for the nanofilter array device can be further optimized to achieve the uniform gap. These devices could be a key to the high-throughput nanofluidic sample-preparation microsystems.en_US
dc.description.statementofresponsibilityby Pan Mao.en_US
dc.format.extent94 leavesen_US
dc.format.extent5427004 bytes
dc.format.extent5430936 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582
dc.subjectMechanical Engineering.en_US
dc.titleFabrication and characterization of nanofluidic channels for studying molecular dynamics in confined environmentsen_US
dc.typeThesisen_US
dc.description.degreeS.M.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineering
dc.identifier.oclc69018170en_US