| dc.contributor.advisor | Leon R. Glicksman and Marilyne Anderson. | en_US |
| dc.contributor.author | McGuire, Molly E | en_US |
| dc.contributor.other | Massachusetts Institute of Technology. Dept. of Architecture. | en_US |
| dc.date.accessioned | 2006-11-07T12:29:23Z | |
| dc.date.available | 2006-11-07T12:29:23Z | |
| dc.date.copyright | 2005 | en_US |
| dc.date.issued | 2005 | en_US |
| dc.identifier.uri | http://hdl.handle.net/1721.1/34487 | |
| dc.description | Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Architecture, 2005. | en_US |
| dc.description | Includes bibliographical references (p. 94-96). | en_US |
| dc.description.abstract | An operational algorithm for blind angle control is developed to optimize the daylighting performance of a system of reflective Venetian blinds. Numerical modeling and experiment confirm that independent control of alternating blinds yields adequate visual comfort and daylight distribution to a distance of 10 m from the window under most clear sunny and overcast sky types. Under overcast sky conditions, all blinds are set to a uniform angle which optimizes light redirection to 10 m. For cases of direct solar incidence, alternating blinds are used for shading and light redirection and adjusted with changing solar position. For low solar angles, a set of blind angle configurations is developed utilizing blind-blind reflections to maximize light penetration. | en_US |
| dc.description.statementofresponsibility | by Molly E. McGuire. | en_US |
| dc.format.extent | 96 p. | en_US |
| dc.format.extent | 3756747 bytes | |
| dc.format.extent | 3760710 bytes | |
| dc.format.mimetype | application/pdf | |
| dc.format.mimetype | application/pdf | |
| dc.language.iso | eng | en_US |
| dc.publisher | Massachusetts Institute of Technology | en_US |
| dc.rights | M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. | en_US |
| dc.rights.uri | http://dspace.mit.edu/handle/1721.1/7582 | |
| dc.subject | Architecture. | en_US |
| dc.title | A system for optimizing interior daylight distribution using reflective Venetian blinds with independent blind angle control | en_US |
| dc.type | Thesis | en_US |
| dc.description.degree | S.M. | en_US |
| dc.contributor.department | Massachusetts Institute of Technology. Department of Architecture | |
| dc.identifier.oclc | 70786744 | en_US |