Show simple item record

dc.contributor.advisorOtto K. Harling.en_US
dc.contributor.authorGao, Weien_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Nuclear Engineering.en_US
dc.date.accessioned2006-11-07T16:47:48Z
dc.date.available2006-11-07T16:47:48Z
dc.date.copyright2005en_US
dc.date.issued2005en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/34653
dc.descriptionIncludes bibliographical references (p. 164-165).en_US
dc.descriptionThesis (S.M.)--Massachusetts Institute of Technology, Dept. of Nuclear Engineering, 2005.en_US
dc.description.abstract(cont.) A storage system was designed to contain the lithium-6 filter safely when it is not in use. A mixed field dosimetry method was used to measure the photon, thermal neutron and fast neutron dose. The measured advantage depth is 9.3 ± 0.1cm without filter and 9.9 ± 0.1cm with 8mm lithium-6 filter. The result is consistent with the result of Monte Carlo calculation.en_US
dc.description.abstractThe design of a lithium-6 filter to be used in Boron Neutron Capture Therapy was developed. The lithium-6 filter increases the average energy of the epithermal neutrons in the epithermal neutron beam. This filter allows the beam to be used for effective BNCT treatment at greater depth in tissue. Based on Monte Carlo calculations, 8mm thick lithium-6 filter was found to be the optimum filter thickness for the MIT fission converter based epithermal neutron beam (FCB). The highly reactive lithium metal filter is sealed with aluminum covers against the humidity and surrounding air. A well shielded and convenient frame was also designed to hold the lithium-6 filter. The frame is separated into two parts. The fixed part of the frame will be mounted into the patient collimator of the FCB and provides a slot for the lithium-6 filter. The filter itself will be connected to the movable part of the frame and slid in and out of the beam through a pair of roller bearing tracks like a vertical drawer. Both parts of the frame are built with borated polyethylene (RICORAD) and steel to insure good shielding. Many safety issues have been considered in the design including tritium production, nuclear heating, pressure from released gases and radiation leakage on the side of the collimator.en_US
dc.description.statementofresponsibilityby Wei Gao.en_US
dc.format.extent165 p.en_US
dc.format.extent5085341 bytes
dc.format.extent5078361 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypeapplication/pdf
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582
dc.subjectNuclear Engineering.en_US
dc.titleLithium-6 filter for a fission converter-based Boron Neutron Capture Therapy irradiation facility beamen_US
dc.title.alternativeLithium-six filter for a fission converter-based BNCT irradiation facility beamen_US
dc.typeThesisen_US
dc.description.degreeS.M.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Nuclear Engineeringen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Nuclear Science and Engineering
dc.identifier.oclc70691894en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record