Show simple item record

dc.contributor.advisorIan W. Hunter.en_US
dc.contributor.authorEllingson, Elizabeth A. (Elizabeth Ann), 1979-en_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Mechanical Engineering.en_US
dc.date.accessioned2007-02-21T11:24:41Z
dc.date.available2007-02-21T11:24:41Z
dc.date.copyright2001en_US
dc.date.issued2001en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/36105
dc.descriptionThesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2001.en_US
dc.descriptionIncludes bibliographical references (p. 37).en_US
dc.description.abstractAn experimental study was performed to determine a simultaneous visual and electrocardiogram measurement of zebrafish embryos. One zebrafish embryo was placed between two electrodes and the electrical signal was amplified 100 times, then a computer recorded the data. The visual reading of the zebrafish heart rate was obtained by viewing the embryo under a microscope. A variety of approaches were investigated to determine the heart rate including amplification, noise filtering and data manipulation. Noise was a significant obstacle in determining the zebrafish embryo's heart rate. Therefore, the signal was smoothed, digitally filtered, and a system transfer function was determined to extract the heart rate from the noisy signal. After the data manipulation, the electrical signal appeared to correspond to the visual reading of the heart rate. Providing a simultaneous visual and electrical measurement of the heart rate can lead to a better understanding of cardiological genetic mutations. This method of measuring the heart rate can supply information on the strength and pattern of the heartbeat, and also detect irregularities in the beat, which could lead to further understanding of cardiological genetic mutations and other related health problems in the future.en_US
dc.description.statementofresponsibilityby Elizabeth A. Ellingson.en_US
dc.format.extent48 p.en_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582
dc.subjectMechanical Engineering.en_US
dc.titleSimultaneous visual and electro-cardiogram measurements of zebrafish embryosen_US
dc.typeThesisen_US
dc.description.degreeS.B.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineering
dc.identifier.oclc50102436en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record