Search
Now showing items 1-2 of 2
Fatal Void Size Comparisons in Via-Below and Via-Above Cu Dual-Damascene Interconnects
(2004-01)
The median-times-to-failure (t₅₀’s) for straight dual-damascene via-terminated copper interconnect structures, tested under the same conditions, depend on whether the vias connect down to underlaying leads ...
Investigation of the Fundamental Reliability Unit for Cu Dual-Damascene Metallization
(2002-01)
An investigation has been carried out to determine the fundamental reliability unit of copper dual-damascene metallization. Electromigration experiments have been carried out on straight via-to-via interconnects in the ...