Show simple item record

dc.contributor.advisorLaurence R. Young.en_US
dc.contributor.authorSamuelson, Heather Marieen_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Mechanical Engineering.en_US
dc.date.accessioned2007-03-12T17:45:57Z
dc.date.available2007-03-12T17:45:57Z
dc.date.copyright2006en_US
dc.date.issued2006en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/36703
dc.descriptionThesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2006.en_US
dc.descriptionPage 54 blank.en_US
dc.descriptionIncludes bibliographical references (p. 37-38).en_US
dc.description.abstractThe MIT Man Vehicle Lab (MVL) is currently performing research on the effects of rotational artificial gravity on humans through the use of a short-radius centrifuge. The MVL centrifuge allows subjects to spin in the supine position with their heads at the center of rotation and their feet facing outwards. To collect information regarding actual forces experienced by a subject while on the centrifuge, a set of scales was designed specifically to measure the equivalent of the human body's weight in artificial gravity. These were mounted on board a stair stepper exercise device to measure the forces exerted at the feet of subjects while exercising. Exercise is particularly important in preventing microgravity-induced deconditioning of the body and without exercise a deconditioned subject might not be able to withstand the stress of experiencing artificial gravity. The primary focus of the research is to gain a better understanding of the overall effects resulting from artificial gravity on humans and eventually to alleviate undesirable ones. The Contek WCS-20® bathroom scale was redesigned to fit on board the stair stepper device on the centrifuge and to safely and securely measure the forces exerted by each foot of a subject while exercising.en_US
dc.description.abstract(cont.) It was also modified to give continuous force readouts; measurements were made while a subject was performing simple exercises on a stair stepper device in artificial gravity. The subject was spun at 0, 12.5, 23 and 30 rpm on the centrifuge and force measurements were taken at each speed. The forces from the two scales (left foot and right foot) sum to give the subject's total equivalent weight at each rotational speed. In addition, the forces exerted radially by the subject vary as he altered his body's distance from the center of the centrifuge through the series of exercises. These scales can be used to provide foot force data and, from this, a better understanding can be gained of the overall effects of artificial gravity on the human body.en_US
dc.description.statementofresponsibilityby Heather Marie Samuelson.en_US
dc.format.extent54 p.en_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582
dc.subjectMechanical Engineering.en_US
dc.titleScales modified for use on board the human centrifuge in the MIT Man Vehicle Laben_US
dc.typeThesisen_US
dc.description.degreeS.B.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineering
dc.identifier.oclc77550073en_US


Files in this item