Show simple item record

dc.contributor.advisorSimona Socrate.en_US
dc.contributor.authorJohnson, Timothy Paul Mahalen_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Mechanical Engineering.en_US
dc.date.accessioned2007-08-03T18:26:31Z
dc.date.available2007-08-03T18:26:31Z
dc.date.copyright2005en_US
dc.date.issued2005en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/38294
dc.descriptionThesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2005.en_US
dc.descriptionIncludes bibliographical references (p. 185-188).en_US
dc.description.abstractThe split-Hopkinson pressure bar (SHPB) technique has been in use in one form or another for more than fifty years and has recently gained a great deal of attention for its ability to characterize materials such as metals, plastics, and even stiff foams at strain rates of up to 105 sec-1. Historically, however, numerous obstacles have stood in the way of applying this technique to softer biological tissues. This study is aimed at bridging this gap by employing various innovations in the field of split-Hopkinson pressure bar techniques (including hollow aluminum and solid polymeric pressure bars) to the characterization of trabecular bone. A preliminary study is conducted on a polyurea (PU) blend to assess the advantages and shortcomings of these approaches, as well as to validate the results obtained with each. Bovine trabecular bone with marrow in-situ, which was chosen for its ability to be tested with a wide spectrum of techniques, is then characterized with the selected techniques at rates of up to 1300 s-1 and strains of 0.07. The results are presented for each technique in the form of engineering stress vs. engineering strain curves.en_US
dc.description.abstract(cont.) Average trend curves are also provided. Unfortunately, many of the samples were too damaged to allow for accurate measurement of apparent density. Consequently, a study into the effect of density on high strain rate responses is left as future work. Recommendations are made for increasing the strain imposed on the samples and suggestions for future studies on both trabecular bone and softer biological tissues are put forward.en_US
dc.description.statementofresponsibilityby Timothy Paul Mahal Johnson.en_US
dc.format.extent188 p.en_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582
dc.subjectMechanical Engineering.en_US
dc.titleHigh strain rate mechanical characterization of trabecular bone utilizing the split-Hopkinson pressure bar techniqueen_US
dc.typeThesisen_US
dc.description.degreeS.M.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineering
dc.identifier.oclc153314157en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)