Show simple item record

dc.contributor.advisorH. Harry Asada.en_US
dc.contributor.authorWade, Eric R. (Eric Randolph), 1978-en_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Mechanical Engineering.en_US
dc.date.accessioned2007-08-29T19:07:56Z
dc.date.available2007-08-29T19:07:56Z
dc.date.copyright2007en_US
dc.date.issued2007en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/38542
dc.descriptionThesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2007.en_US
dc.descriptionThis electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.en_US
dc.descriptionIncludes bibliographical references (p. 112-116).en_US
dc.description.abstractWearable computing applications are becoming increasingly present in our lives. Of the many wearable computing applications, wearable health monitoring may have the most potential to make a lasting positive impact. The ability to remotely monitor physiological signals such as respiration, motion, and temperature has benefits for populations such as elderly citizens, fitness professionals, and soldiers in the battlefield. To fully integrate wearable networks into a user's daily life, these systems must be minimally invasive and minimally intrusive. At the same time, such wearable networks require multiple sensors and electronic components to be mounted on the body. Unfortunately, typical off-the-shelf components of this nature are heavy, bulky, and don't integrate well with the human form. Thus, it is critical to figure out how best to minimize the physical and mental burden that these systems place on the user. To address these problems, we propose a new method of designing wearable health monitoring networks by combining electrically conductive fabrics and power-line communication technology. Electrically conductive fabrics are useful in that they feel and behave like normally worn clothing but also have the ability to transmit data and power.en_US
dc.description.abstract(cont.) To fully exploit the conductive fabric as a transmission medium, we also use power-line communication technology. Power-line communication allows for simultaneous power and data transmission over a shared medium. The use of these two technologies will allow us to significantly reduce the amount of metal cabling on the body and to reduce overall system bulk and weight. With this project, we design the DC-PLC system that will act as the physical layer of the architecture. Next, we construct a prototype body area network, and derive analytical models for predicting garment electrostatic and electro-dynamic properties using Maxwell's equations, and verify using empirical data and finite-element analysis. Finally, we will determine relevant rules and guidelines for the design and construction of such garments.en_US
dc.description.statementofresponsibilityby Eric R. Wade.en_US
dc.format.extent116 p.en_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582
dc.subjectMechanical Engineering.en_US
dc.titleA body area network for wearable health monitoring : conductive fabric garment utilizing DC-power-line carrier communicationen_US
dc.typeThesisen_US
dc.description.degreePh.D.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineering
dc.identifier.oclc165228076en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record