MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Graduate Theses
  • View Item
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Graduate Theses
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Fabrication of microfluidic devices for artificial respiration

Author(s)
Park, Hyesung, Ph. D. Massachusetts Institute of Technology
Thumbnail
DownloadFull printable version (13.38Mb)
Other Contributors
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Advisor
Todd Thorsen and Richard Gilbert.
Terms of use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582
Metadata
Show full item record
Abstract
We are developing elastomeric polydimethylsiloxane (PDMS) microfluidic devices incorporated with photoactive thin films to create an implantable artificial respiration platform. Whereas state-of-the-art respiration support machines deliver oxygen gas directly to the blood via external macroscale devices, our technique utilizes a biomimetic photocatalytic process to generate energy from light and thus produce dissolved oxygen from water which is already present in the blood. Blood oxygenation will be achieved by the interaction between the photoactivated metal oxide film and blood in the setting of a molded microfluidic conduit, providing a stable and implantable oxygenation platform. As a basic, scalable building block, we developed a noble "network" design which was structurally similar to the native pulmonary capillary network. The interconnected channel geometry was designed in such a way to minimize shear stress and reduce hemolysis and thrombosis inside the microchannel. It allowed alternative flow pathways in the event of single channel occlusion while minimizing the establishment of detrimental pressure gradients. The hemocompatibility analysis demonstrated that the network construct showed acceptable levels of hemolysis rate (< 8%) and thrombus formation.
 
(cont.) Critical to the success of this project is the understanding of the manufacture parameters for microfluidic devices molded from elastomeric materials like PDMS. In the initial development of our work, we performed the following three tasks to generate manufacture protocols for elastomeric microfluidic devices that will be ultimately used for biological applications: 1) Curing schedules of the heat-cure PDMS elastomers under various fabrication parameters were characterized. 2) The interlayer bonding chemistry of the double layer PDMS device was analyzed followed by subsequent mechanical analysis. 3) The efficacy of various surface treatment techniques on hydrophobic PDMS surfaces was investigated using fluorescently tagged bacteria (E. Coli) flowed through microchannels as reporter particles to measure non-specific adhesion, which will provide useful information in minimizing channel fouling for biological applications.
 
Description
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2007.
 
Includes bibliographical references (p. 101-108).
 
Date issued
2007
URI
http://hdl.handle.net/1721.1/40370
Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Publisher
Massachusetts Institute of Technology
Keywords
Mechanical Engineering.

Collections
  • Graduate Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.