Development of a collapsible guard component for a novel surgical instrument

Author(s)
Buckley, Darragh
Thumbnail
DownloadFull printable version (1.163Mb)
Other Contributors
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Advisor
Alexander H. Slocum.
Terms of use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582
Metadata
Show full item record
Abstract
The Endoblend is a novel surgical device for use in laparoscopic hysterectomy surgery. Laparoscopic hysterectomy surgery requires that the uterus be removed through a laparoscopic port. To achieve this, the Endoblend liquefies the uterus through the use of cutting blades. The Endoblend has a stem containing aspiration tubes, irrigation tubes and power transmission elements. A spinning blade is attached at the end of this stem for the purpose of liquefying previously separated tissues such that they can be removed from the abdominal cavity through the aspiration tubes. In order to effectively process the tissues, they must be placed with a sealed enclosure. This enclosure is at risk of being compromised by the spinning blades and therefore the need arises for a guard module to prevent this. The guard module must function to direct the tissue towards the blades and prevent any tearing of the enclosure. It must also be capable of fitting through a 15 mm laparoscopic port. A guard has been developed comprising of three Nitinol rings and an ultra-high molecular weight polyethylene fiber. The guard's functionality has been tested and the guard is capable of meeting all the functional requirements.
Description
Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2007.
 
Includes bibliographical references (p. 17).
 
Date issued
2007
URI
http://hdl.handle.net/1721.1/40395
Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Publisher
Massachusetts Institute of Technology
Keywords
Mechanical Engineering.

Collections
  • Undergraduate Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.