Show simple item record

dc.contributor.advisorH. Frederick Bowman.en_US
dc.contributor.authorSavage, Christopher (Christopher R.)en_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Mechanical Engineering.en_US
dc.date.accessioned2008-02-27T22:30:14Z
dc.date.available2008-02-27T22:30:14Z
dc.date.copyright2007en_US
dc.date.issued2007en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/40480
dc.descriptionThesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2007.en_US
dc.descriptionIncludes bibliographical references (leaf 22).en_US
dc.description.abstractAtherosclerosis is a systemic disease that causes plaque accumulation in arteries and diminished endothelial function. Because it is rarely identified until serious symptoms appear, there is value in a noninvasive technique for detecting atherosclerosis using characterization of endothelial dysfunction. Dr. Bowman devised a thermal sensing device to measure the temperature reflex of the hand subsequent to induced hyperemia. We created an interface that would securely and reproducibly place the thermal sensor in contact with skin. Our interface (the bead holder) was designed and redesigned until we reached a successful and viable product. The bead holder iterative design process involved creating solid models, rapid-prototyping, and finally testing the effectiveness of the interface. After our first production run of ten acrylic bead holders, we installed a thermistor in each holder and achieved a satisfactory fit. Moreover, the thermistor was easily oriented into the holder and fit snugly. We must continue the design optimization process to determine the best distance for the thermistor bead to extend beyond the holder housing to optimize fluid transport in capillary collapse. We will also consider fabrication alternatives to 3-D printing such as injection molding.en_US
dc.description.statementofresponsibilityby Christopher Savage.en_US
dc.format.extent22 leavesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582
dc.subjectMechanical Engineering.en_US
dc.titleDesign of a bead holder for thermal atherosclerosis sensoren_US
dc.typeThesisen_US
dc.description.degreeS.B.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineering
dc.identifier.oclc191800528en_US