Show simple item record

dc.contributor.advisorRahul Sarpeshkar.en_US
dc.contributor.authorBaker, Michael W. (Michael Warren), 1977-en_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.en_US
dc.date.accessioned2008-02-27T22:32:24Z
dc.date.available2008-02-27T22:32:24Z
dc.date.copyright2007en_US
dc.date.issued2007en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/40494
dc.descriptionThesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2007.en_US
dc.descriptionIncludes bibliographical references (p. 171-179).en_US
dc.description.abstractCochlear implants, or bionic ears, restore hearing to the profoundly deaf by bypassing missing inner-ear hair cells in the cochlea and electrically stimulating the auditory nerve. For miniaturized cochlear implants, including behind-the-ear (BTE) models, power consumption is the chief factor in determining cost and patient convenience. This thesis reports on the design of a low-power bionic ear system by addressing three critical signal and power processing subsystems in low-cost CMOS ICs. First, the design of a low-power current-mode front-end for subminiature microphones demonstrates 78dB dynamic range performance with attention to RF noise and supply immunity. Second, hearing-impaired patients need strategies that decide intelligently between listening conditions in speech or noise. This work describes an automatic gain control (AGC) design which uses programmable hybrid analog-digital current-mode feedback to implement a dual-loop strategy, a well-known algorithm for speech in noisy environments. The AGC exhibits level-invariant. stability, programmable time constants and consumes less than 36pW. Third, a feedback-loop technique is explored for analyzing and designing RF power links for transcutaneous bionic ear systems.en_US
dc.description.abstract(cont.) Using feedback tools to minimize algebraic manipulations, this work demonstrates conditions for optimal voltage and power transfer functions. This theory is applied to a bionic implant system designed for load power consumptions in the 1mW - 10mW range, a low-power regime not significantly explored in prior designs. Link efficiencies of 74% and 54% at 1-mm and 10-mm coil separations, respectively, are measured, in good agreement with theoretical predictions. A full cochlear implant system with signal and power processing is explored incorporating the front-end, AGC, and RF power link, as well as analog signal processing channels. This design uses channel data to feedforward program the just-needed electrode power level. My implant system consumes 3mW of power for all audio processing and a stimulation power of 1mW. A fixed-power version of this system dissipates 2.2mW for 1mW of internal stimulation power. As many commercial systems with similar specifications consume 40mW - 80mW, this effort promises a significant reduction in cochlear implant power consumption and cost.en_US
dc.description.statementofresponsibilityby Michael W. Baker.en_US
dc.format.extent179 p.en_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582
dc.subjectElectrical Engineering and Computer Science.en_US
dc.titleA low-power cochlear implant systemen_US
dc.typeThesisen_US
dc.description.degreePh.D.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
dc.identifier.oclc191805528en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record