dc.description.abstractVaccines are very sensitive to temperature, needing to be held between 2 and 80°C to maintain potency. In developing countries where electricity and fuel supplies are unreliable, many vaccines are ruined due to thermal exposure. These are also the locations where vaccines are needed the most, yet often many of the vaccines given are ineffective. Long holdover vaccine coolers are designed to maintain a proper internal temperature during long periods of power loss. The most prevalent technology is the ice-lined cooler, but in the field these often have problem with freezing the vaccines. A vaccine cooler was designed that modifies the ice-jacket idea by separating the ice compartment and the vaccine chamber, connecting them through a heat transfer regulating device. The objective of this research is to design and prototype the heat transfer regulating device. After several design iterations a cooling loop filled with R-134a made of 1/8 piping, a 0.055 in ID capillary, and a Clippard normally-closed valve was combined with a modified car thermostat, using peanut oil as its working fluid, to create a thermosyphon type heat transfer device with a safety shutoff to prevent freezing. The prototype was manufactured and tested. It was found that with the proper amount of working fluid, it is possible to run the cooling loop at 4°C and pull heat from the vaccine chamber side to the ice. The peanut oil thermostat was tested and was found to open at a slightly lower temperature than expected, 2.5°C, but still within range. These results indicate that the concept is viable and should be tested in the vaccine cooler.en_US
dc.description.statementofresponsibilityby Cynthia D. Walker.en_US
dc.format.extent58 p.en_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectMechanical Engineering.en_US
dc.titleDesign and manufacture of low cost vaccine cooleren_US