JavaScript is disabled for your browser. Some features of this site may not work without it.

Effective thermal conductivity measurements relevant to deep borehole nuclear waste disposal

Author(s)
Shaikh, Samina
Thumbnail
DownloadFull printable version (5.215Mb)
Other Contributors
Massachusetts Institute of Technology. Dept. of Nuclear Science and Engineering.
Advisor
Michael J. Driscoll.
Terms of use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582
Metadata
Show full item record
Abstract
The objective of this work was to measure the effective thermal conductivity of a number of materials (particle beds, and fluids) proposed for use in and around canisters for disposal of high level nuclear waste in deep boreholes. This information is required to insure that waste temperatures will not exceed tolerable limits. Such experimental verification is essential because analytical models and empirical correlations can not accurately predict effective thermal conductivities for complex configurations of poorly characterized media, such as beds of irregular particles of mixed sizes. The experimental apparatus consisted of a 2.54 cm. diameter cylindrical heater (heated length = 0.5 m) , surrounded by a 5.0 cm inner diameter steel tube. Six pairs of thermocouples were located axially on the inside of the heater sheath, and in grooves on the air-fan-cooled outer tube. Test media were used to fill the annular gap, and the temperature drop across the gap measured at several power levels covering the range of heat fluxes expected on a waste canister soon after emplacement. Values of effective thermal conductivity were measured for air, water; particle beds of sand, SiC, graphite and aluminum; and an air gap subdivided by a thin metal sleeve insert. Results are compared to literature values and analytical models for conduction, convection and radiation. Agreement within a factor of 2 was common, and the results confirm the adequacy, and reduce the uncertainty of prior borehole system design calculations. All particle bed data fell between 0.3 and 0.5 W/moC, hence other attributes can determine usage.
Description
Thesis (S.M. and S.B.)--Massachusetts Institute of Technology, Dept. of Nuclear Science and Engineering, 2007.
 
Includes bibliographical references (leaves 106-107).
 
Date issued
2007
URI
http://hdl.handle.net/1721.1/41301
Department
Massachusetts Institute of Technology. Department of Nuclear Science and Engineering
Publisher
Massachusetts Institute of Technology
Keywords
Nuclear Science and Engineering.

Collections
  • Graduate Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.