Show simple item record

dc.contributor.advisorJacquelyn C. Yanch.en_US
dc.contributor.authorHembrador, Sheena (Sheena Marie C.)en_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Nuclear Science and Engineering.en_US
dc.date.accessioned2008-05-19T15:57:52Z
dc.date.available2008-05-19T15:57:52Z
dc.date.copyright2006en_US
dc.date.issued2006en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/41590
dc.descriptionThesis (S.B.)--Massachusetts Institute of Technology, Dept. of Nuclear Science and Engineering, 2006.en_US
dc.descriptionIncludes bibliographical references (leaf 47).en_US
dc.description.abstractThe biological effects of acute, high doses of radiation are well understood. However, the effects of chronic, low doses are not as clear. Mice irradiation experiments to study the correlation of biological effects with chronic low dose rates are underway in order to make conclusions about the effects of low doses. Yet, in order to do so, the level of dose provided to the animals must be determined. This paper examines methods of ascertaining the dose rate delivered to mice by photons from an 125Iodine filled flood phantom source. Two distinct methods were used. First, Optically Stimulated Luminescence (OSL) Dosimeters were placed in an array over an area slightly larger than the irradiation area. The dose equivalent they each reported was recorded weekly. Secondly, a series of simulations were performed using MCNP to calculate the expected dose equivalent reported by those dosimeters. Comparison of the dosimeters' recorded dose to MCNP's calculated dose showed agreement within experimental and statistical uncertainty for 82% of the measurements. This high level of agreement demonstrates that the MCNP simulation approach produces reliable results. After this was shown, other MCNP simulations were performed to determine the dose equivalent to the mice in cages placed above the 125I filled phantom. The simulation showed an average dose equivalent of 656 t 108 mrem per week, with a range of 866 t 33 mrem/week to 399 t 18 mrem/week. The dosimetry methods developed in this report are not unique to this dose level, and can be used in future mouse studies to determine dose rates at other orders of magnitude.en_US
dc.description.statementofresponsibilityby Sheena Hembrador.en_US
dc.format.extent47 leavesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectNuclear Science and Engineering.en_US
dc.titleDosimetry of ¹²⁵Iodine protons for in vivo mouse irradiation studyen_US
dc.typeThesisen_US
dc.description.degreeS.B.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Nuclear Science and Engineering
dc.identifier.oclc213495856en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record