Show simple item record

dc.contributor.advisorDavid R. Wallace.en_US
dc.contributor.authorCarvey, Andrew W. (Andrew Williams), 1980-en_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Mechanical Engineering.en_US
dc.date.accessioned2008-09-03T15:16:28Z
dc.date.available2008-09-03T15:16:28Z
dc.date.copyright2006en_US
dc.date.issued2006en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/42300
dc.descriptionThesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2006.en_US
dc.descriptionIncludes bibliographical references (leaves 106-108).en_US
dc.description.abstractLocomotion assistive devices can be broadly classified as either being passive or powered. Both have been created to aid in the leg's generation of a ground reaction force which supports the torso during locomotion, yet their inherent design has limited their functional growth to date. While many differing gait simulations have demonstrated stable solutions for lossless gait cycles, passive orthoses only diminish the user's impediment, and though powered gait exoskeletons can augment strength and endurance, they are limited by their energy demanding actuators. In response to these two extremes, an energy efficient locomotion assist device was developed from the basis of lossless gait models that did not require external power, and augmented locomotion by harvesting the inherent energy associated with the gait cycle. The simplest anthropomorphic leg can be modeled with a peg-leg shank, a knee, a thigh and a point mass for the head, arms and torso. Using a tuned non-linear hardening torsion spring at the knee joint, the torso support that is required between the ground and pelvis for lossless gait simulations can be generated; allowing the close physical realization of the theoretical. It was found that a single torsion spring can generate the leg thrusts necessary for a realistic range of walking and running gait velocities without the addition of any external power. While frictional losses do inhibit the locomotion assist device's efficiency, since the device functions in parallel with the user's leg, any losses can be supplemented with minimal muscular activity. These results give strong indication that a new avenue of gait assistive and gait augmenting devices that require minimal actuation energy is feasible.en_US
dc.description.statementofresponsibilityby Andrew Williams Carvey.en_US
dc.format.extent108 leavesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectMechanical Engineering.en_US
dc.titleA metabolically efficient leg braceen_US
dc.typeThesisen_US
dc.description.degreeS.M.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineering
dc.identifier.oclc232359375en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record