Base isolation case study
Author(s)
Ching, Kenneth A. (Kenneth Apostol)
DownloadFull printable version (16.04Mb)
Other Contributors
Massachusetts Institute of Technology. Dept. of Civil and Environmental Engineering.
Advisor
Jerome J. Connor.
Terms of use
Metadata
Show full item recordAbstract
The primary objective of this thesis is the introduction of the current code, ASCE 7-05 into the base isolation design and the analysis of base isolation response due to seismic forces. An eight story irregular structure is modeled using SAP2000 structural program. The time history of Northridge earthquake is used as a seismic forcing function of the structure. The base isolator is designed by using the principle of bilinear modeling. Therefore, the base isolation system is analyzed using the non-linear time history analysis. The response of the isolation system is analyzed, and especially its hysteresis loop. Results show that the inputted energy of the seismic forces is dissipated by hysteretic and modal damping.
Description
Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Civil and Environmental Engineering, 2008. Includes bibliographical references (leaf 51).
Date issued
2008Department
Massachusetts Institute of Technology. Department of Civil and Environmental EngineeringPublisher
Massachusetts Institute of Technology
Keywords
Civil and Environmental Engineering.