dc.description.abstractThree ionization chambers with different geometries have been constructed and filled with dielectric liquids for detection of fast neutrons. The three dielectric liquids studied were Tetramethylsilane (TMS), Tetramethylpentane (TMP), and Isooctane, which each have intrinsic properties that make them attractive for fast neutron detection. Their electronic properties are similar to those of condensed noble gases, but they don't require cryogenic temperatures to maintain liquid phase. However, like condensed noble gases, they do require a high level of purity. A stainless steel purification system was constructed to purify the liquids and the purity was monitored by an ionization chamber with a 241Am source inside. The three liquid detectors were exposed to 250keV x-rays from an orthovoltage x-ray tube and neutrons (1.4-12MeV) from a 1-Ci 239Pu-Be source. Experimental data show that an ionization chamber filled with dielectric liquid is capable of detecting fast neutrons in pulse mode. While chamber 1, chamber 2, and chamber 3 (filled with TMS) did not respond to the Pu-Be source, chamber 3 (filled with TMP and Isooctane) successfully detected the presence of neutrons. Data also show that the chambers could not detect gamma rays from 1[mu]Ci Co-60 and Cs-137 check sources. In addition, the chambers could detect 250 keV x-rays in current mode, but not pulse mode. These results present positive implications for the gamma-blindness of the dielectric liquids studied.en_US
dc.description.statementofresponsibilityby Erin M. Boyd.en_US
dc.format.extent111 leavesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectNuclear Science and Engineering.en_US
dc.titleDielectric liquid ionization chambers for detecting fast neutronsen_US