Show simple item record

dc.contributor.advisorGeorge Barbastathis.en_US
dc.contributor.authorWatson, Jonathan Men_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Mechanical Engineering.en_US
dc.date.accessioned2009-03-16T19:51:29Z
dc.date.available2009-03-16T19:51:29Z
dc.date.copyright2008en_US
dc.date.issued2008en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/44854
dc.descriptionThesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2008.en_US
dc.descriptionIncludes bibliographical references (leaves 144-148).en_US
dc.description.abstractIn this thesis, the properties of transmission-mode volume phase holograms as spatial-spectral filters in optical systems for microscopic medical imaging are evaluated. In experiment, the relationship between the angle of incidence and diffraction efficiency are invesitgated for wavelength-detuned multiplex holograms to establish the limits of the narrow bandwidth lateral field of view. The depth selectivity of the microscope with a volume hologram pupil is also measured and found to vary significantly with recording parameters and lateral shift of the probe point source in object space. This experiment is modified to incorporate controlled levels of spherical aberration, where the effect on the depth selectivity is evaluated. A novel resolution target designed specifically for the evaluation of this imaging system is described and imaged. A flexible approach based on the 1st-order Born approximation is implemented to simulate all aspects of the imaging system with a multiplex volume hologram pupil. The simulation is then used to verify and expand upon the experimental results. A mathematical treatment of the nature of the anomalous apparent curvature of the diffraction image is performed, showing that a volume grating recorded in plane has weak out-of-plane spatial filtering behavior.en_US
dc.description.statementofresponsibilityby Jonathan M. Watson.en_US
dc.format.extent171 leavesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectMechanical Engineering.en_US
dc.titleEvaluation of spatial-spectral filtering in non-paraxial volume holographic imaging systemsen_US
dc.typeThesisen_US
dc.description.degreeS.M.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineering
dc.identifier.oclc301735256en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record