Show simple item record

dc.contributor.advisorJames G. Fujimoto.en_US
dc.contributor.authorSrinivasan, Vivek Jayen_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.en_US
dc.date.accessioned2009-06-30T16:11:08Z
dc.date.available2009-06-30T16:11:08Z
dc.date.copyright2008en_US
dc.date.issued2008en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/45748
dc.descriptionThesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2008.en_US
dc.descriptionIncludes bibliographical references.en_US
dc.description.abstractOptical Coherence Tomography (OCT) is an emerging optical biomedical imaging technology that enables cross-sectional imaging of scattering tissue with high sensitivity and micron-scale resolution. In conventional OCT, the reference arm path length in a Michelson interferometer is scanned in time to generate a profile of backscattering versus depth from the sample arm. In conventional OCT, a broadband, low coherence light source is used to achieve high axial resolution. However, clinical and research applications of conventional OCT have been limited by low imaging speeds. Recently, new Fourier domain OCT detection methods have enabled speeds of ~20,000-40,000 axial scans per second, which are ~50-100x faster than conventional OCT. These methods are called "Fourier domain" because they detect the interference spectrum and do not require mechanical scanning of the reference arm path length in time. In this thesis, two different technologies for Fourier domain OCT are investigated. The first technology, called spectral OCT, uses a broadband light source and a spectrometer to measure the interference spectrum. The second technology, called swept source OCT, uses a rapidly tunable narrowband laser to measure the interference spectrum over time. Applications of these new technologies for retinal imaging are illustrated, including three-dimensional retinal imaging in animal models, clinical imaging of retinal pathologies, quantification of photoreceptor morphology, and functional imaging of intrinsic stimulus-induced scattering changes in the retina. Finally, using a rapidly tunable laser, ultrahigh-speed swept source OCT imaging at 249,000 axial scans per second, roughly three orders of magnitude faster than conventional OCT, is demonstrated. This technology is applied for three-dimensional snapshots of the retina and optic nerve head and unprecedented visualization of retinal anatomy.en_US
dc.description.statementofresponsibilityby Vivek Jay Srinivasan.en_US
dc.format.extent234 leavesen_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectElectrical Engineering and Computer Science.en_US
dc.titleHigh-speed Fourier domain Optical Coherence Tomography for structural and functional imaging of the retinaen_US
dc.title.alternativeHigh-speed Fourier domain OCT for structural and functional imaging of the retinaen_US
dc.typeThesisen_US
dc.description.degreePh.D.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
dc.identifier.oclc298116698en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record