The MIT Libraries is completing a major upgrade to DSpace@MIT.
Starting May 5 2026, DSpace will remain functional, viewable, searchable, and downloadable, however, you will not be able to edit existing collections or add new material.
We are aiming to have full functionality restored by May 18, 2026, but intermittent service interruptions may occur.
Please email dspace-lib@mit.edu with any questions.
Thank you for your patience as we implement this important upgrade.
Design and fabrication of a precision alignment system and package for a two-photon fluorescence imaging device
| dc.contributor.advisor | Martin L. Culpepper. | en_US |
| dc.contributor.author | Chang, Jean H | en_US |
| dc.contributor.other | Massachusetts Institute of Technology. Dept. of Mechanical Engineering. | en_US |
| dc.date.accessioned | 2009-06-30T16:16:13Z | |
| dc.date.available | 2009-06-30T16:16:13Z | |
| dc.date.copyright | 2008 | en_US |
| dc.date.issued | 2008 | en_US |
| dc.identifier.uri | http://hdl.handle.net/1721.1/45776 | |
| dc.description | Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2008. | en_US |
| dc.description | Includes bibliographical references (leaf 24). | en_US |
| dc.description.abstract | A compact, lightweight precision alignment system and package for an endomicroscope was designed and fabricated. The endomicroscope will consist of a millimeter-scale fiber resonator and a two-axis silicon optical bench. The alignment system provided five degrees of freedom and was designed to align the fiber resonator with the microchip with a resolution of one micron. The alignment system consisted of a system of ultra-fine screws and two compliant mechanisms to deamplify the motion of the screw. Finite element analysis was performed to optimize the compliant mechanisms for the desired transmission ratio of 20:1. The alignment system was fabricated and testing showed that the transmission ratios were lower than expected (18.6 for one compliant mechanism and 2.68 for the other). Testing also showed that the alignment system met the functional requirements for the ranges of motion. | en_US |
| dc.description.statementofresponsibility | by Jean H. Chang. | en_US |
| dc.format.extent | 24 leaves | en_US |
| dc.language.iso | eng | en_US |
| dc.publisher | Massachusetts Institute of Technology | en_US |
| dc.rights | M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. | en_US |
| dc.rights.uri | http://dspace.mit.edu/handle/1721.1/7582 | en_US |
| dc.subject | Mechanical Engineering. | en_US |
| dc.title | Design and fabrication of a precision alignment system and package for a two-photon fluorescence imaging device | en_US |
| dc.type | Thesis | en_US |
| dc.description.degree | S.B. | en_US |
| dc.contributor.department | Massachusetts Institute of Technology. Department of Mechanical Engineering | |
| dc.identifier.oclc | 318456030 | en_US |
