Show simple item record

dc.contributor.advisorCarol Livermore.en_US
dc.contributor.authorHill, Tyrone F. (Tyrone Frank), 1980-en_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.en_US
dc.date.accessioned2009-06-30T16:28:53Z
dc.date.available2009-06-30T16:28:53Z
dc.date.copyright2008en_US
dc.date.issued2008en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/45867
dc.descriptionThesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2008.en_US
dc.descriptionIncludes bibliographical references (p. 153-158).en_US
dc.description.abstractChemical Oxygen-Iodine Lasers (COIL) are a technology of interest for industrial and military audiences. COILs are flowing gas lasers where the gain medium of iodine atoms is collisionally pumped by singlet delta oxygen molecules, which are created through the catalyzed multiphase reaction of hydrogen peroxide and chlorine. Currently the use of COIL technology is limited by size and efficiency issues. This thesis seeks to use MEMS technology towards the development of more compact and efficient COIL systems, with a focus on the singlet oxygen generator (SOG) stage. Based on success in other applications, MEMS technology offers opportunities for improved reactant mixing, product separation, and heat transfer in SOGs. A MEMS singlet oxygen generator (or microSOG) is built and demonstrated. The chip features 32 multiplexed packed bed reaction channels and utilizes capillarity effects to separate the gas and liquid products. Cooling channels are arranged on the chip such that they form a cross-flow heat exchanger with the reaction channels. Spontaneous optical emission measurements and mass spectroscopy are used to confirm singlet oxygen production in the chip. A singlet delta oxygen molar flow rate corresponding to a power of 1.37 W was measured in the chip. The singlet oxygen molar flow rate per unit of hardware volume is 6.7x10-2 mol/L/sec, which represents an order of magnitude improvement over sparger and rotary SOG designs. A detailed physical model is developed to understand the behavior of the microSOG. This model is used along with the experimental results to gain insights into the poorly characterized singlet oxygen deactivation coefficients. Clogging and nonlinear hydraulic behavior prevented the first-generation microSOG from performing as well as the models originally suggested. These issues are addressed in a proposed second generation design, which simulations indicate will produce 50% more singlet oxygen per unit of hardware volume than its predecessor.en_US
dc.description.statementofresponsibilityby Tyrone Frank Hill.en_US
dc.format.extent158 p.en_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectElectrical Engineering and Computer Science.en_US
dc.titleMicrochemical systems for singlet oxygen generationen_US
dc.typeThesisen_US
dc.description.degreePh.D.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
dc.identifier.oclc320090756en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record