MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Graduate Theses
  • View Item
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Graduate Theses
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Beam characterization for accelerator-based boron neutron capture therapy using the ⁹Be(d,n) nuclear reaction

Author(s)
White, Susan Marie, 1973-
Thumbnail
DownloadFull printable version (6.726Mb)
Advisor
Jacquelyn C. Yanch.
Terms of use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582
Metadata
Show full item record
Abstract
Use of the ⁹Be(d,n) nuclear reaction for accelerator-based boron neutron capture therapies (AB-BNCT) was investigated. The moderated neutron spectra produced at several deuteron bombarding energies were evaluated in terms of dose rates and dosimetric profiles in a water-filled brain phantom using an existing heavy water moderator and lead reflector assembly. Dosimetry results were obtained using the dual ionization chamber technique coupled with bare and cadmium-covered gold foils. Data have been taken with deuteron beams of 1.3 MeV to 1.8 MeV. As deuteron energy was increased, the tumor dose rate correspondingly improved due to the neutron yield increase. However, the data suggest that the advantage depth decreased, and the ratio of the fast neutron dose rate to the thermal neutron dose rate at a depth of I cm increased, although error bars are significant. All deuteron energies investigated produced a beam that, once moderated, appears viable for AB-BNCT. No conclusion was drawn about the best energy in terms of a high tumor dose rate, a significant advantage depth, and a low fast to thermal neutron dose rate ratio. Treatment times assuming 20 Gy to a tumor located 4 cm deep using a 4 mA accelerator ranged from 18 - 59 minutes, assuming a tumor boron concentration of 40 ppm and RBE values of 1.0 for photons, 3.2 for neutrons, and 3.8 for boron in tumor tissue. The average advantage depth was 6.4 ± 0.7 cm, so these moderated beams could be used to treat tumors near the brain centerline. The ⁹Be(d,n) nuclear reaction is exothermic, and is accessible to inexpensive, small particle accelerators.
Description
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Nuclear Engineering, 1998.
 
Includes bibliographical references (leaves 62-65).
 
Date issued
1998
URI
http://hdl.handle.net/1721.1/50491
Department
Massachusetts Institute of Technology. Department of Nuclear Science and Engineering
Publisher
Massachusetts Institute of Technology
Keywords
Nuclear Engineering

Collections
  • Graduate Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.