dc.description.abstractRotating stall has been stabilized in a single-stage transonic axial flow compressor with inlet distortion using active feedback control. The experiments were conducted at the NASA Lewis Research Center on a single-stage transonic core compressor. An annular array of 12 jet-injectors located upstream of the rotor tip was used for forced response testing and to extend the compressor stable operating range. Results for radial and circumferential inlet distortion are reported. First, the effects of radial distortion on the compressor performance and the dynamic behavior were investigated. Control laws were designed using empirical transfer function estimates determined from forced response results. The transfer functions indicated that the compressor dynamics are decoupled with radial inlet distortion, as they are for the case of undistorted inlet flow. Single- input-single-output (SISO) control strategies were therefore used for the radial distortion controller designs. A circumferential total pressure distortion of about one dynamic head and a 120' extent (DC(60) = 0.61) introduced coupling between the harmonics of circumferential pressure perturbations, requiring multi-variable (MIMO) identification and control design techniques. A careful analysis of the coupled pre-stall compressor dynamics revealed a strong first spatial harmonic, dominated by the well known incompressible Moore-Greitzer mode. Constant gain control and more sophisticated MIMO robust control strategies were used for stabilization with circumferential inlet distortion. Steady axisymmetric injection of 4% of the compressor mass flow resulted in a reduction in stalling mass flow of 9.7% relative to the case with radial inlet distortion and no injection. Use of a robust H, controller with unsteady non-axisymmetric injection achieved a further reduction in stalling mass flow of 7.5%, resulting in a total reduction of 17.2%. Steady injection experiments with circumferential inlet distortion resulted in a 6.2% reduction of stalling mass flow. Constant gain feedback, using unsteady asymmetric injection, yielded a further range extension of 9%. Testing of MIMO robust controllers showed only 2% reduction in stalling mass flow. Instead of further tuning the complex MIMO controllers, the same robust H. controller used for radial distortion was tested. This controller achieved a reduction in stalling mass flow of 10.2% relative to steady injection, yielding a total reduction in stalling mass flow of 16.4%.en_US
dc.description.statementofresponsibilityby Zoltán S. Spakovszky.en_US
dc.format.extent103 p.en_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectAeronautics and Astronauticsen_US
dc.titleActive control of rotating stall in a transonic compressor stage with inlet distortionen_US
dc.typeThesisen_US
dc.description.degreeS.M.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Aeronautics and Astronauticsen_US
dc.identifier.oclc42695842en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record