Show simple item record

dc.contributor.authorHanumara, Nevan Clancy
dc.contributor.authorWalsh, Conor James
dc.contributor.authorSlocum, Alexander H.
dc.contributor.authorSeitel, Alexander
dc.contributor.authorShepard, Jo-Anne
dc.contributor.authorMaier-Hein, Lena
dc.contributor.authorGupta, Rajiv
dc.contributor.authorMeinzer, Hans-Peter
dc.date.accessioned2010-03-17T19:29:55Z
dc.date.available2010-03-17T19:29:55Z
dc.date.issued2009-03
dc.identifier.issn0277-786X
dc.identifier.urihttp://hdl.handle.net/1721.1/52686
dc.description.abstractThe main challenges of Computed Tomography (CT)-guided organ puncture are the mental registration of the medical imaging data with the patient anatomy, required when planning a trajectory, and the subsequent precise insertion of a needle along it. An interventional telerobotic system, such as Robopsy, enables precise needle insertion, however, in order to minimize procedure time and number of CT scans, this system should be driven by an interface that is directly integrated with the medical imaging data. In this study we have developed and evaluated such an interface that provides the user with a point-and-click functionality for specifying the desired trajectory, segmenting the needle and automatically calculating the insertion parameters (angles and depth). In order to highlight the advantages of such an interface, we compared robotic-assisted targeting using the old interface (non-image-based) where the path planning was performed on the CT console and transferred manually to the interface with the targeting procedure using the new interface (image-based). We found that the mean procedure time (n=5) was 22±5 min (non-image-based) and 19±1 min (image-based) with a mean number of CT scans of 6±1 (non-image-based) and 5±1 (image-based). Although the targeting experiments were performed in gelatin with homogenous properties our results indicate that an image-based interface can reduce procedure time as well as number of CT scans for percutaneous needle biopsies.en
dc.language.isoen_US
dc.publisherThe International Society for Optical Engineeringen
dc.relation.isversionofhttp://dx.doi.org/10.1117/12.811507en
dc.rightsArticle is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.en
dc.sourceSPIEen
dc.titleDevelopment and evaluation of a new image-based user interface for robot-assisted needle placements with the robopsy systemen
dc.typeArticleen
dc.identifier.citationSeitel, Alexander et al. “Development and evaluation of a new image-based user interface for robot-assisted needle placements with the Robopsy system.” Medical Imaging 2009: Visualization, Image-Guided Procedures, and Modeling. Ed. Michael I. Miga & Kenneth H. Wong. Lake Buena Vista, FL, USA: SPIE, 2009. 72610X-9. © 2009 SPIE--The International Society for Optical Engineeringen
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineeringen_US
dc.contributor.approverSlocum, Alexander H.
dc.contributor.mitauthorHanumara, Nevan Clancy
dc.contributor.mitauthorWalsh, Conor James
dc.contributor.mitauthorSlocum, Alexander H.
dc.relation.journalProceedings of SPIEen
dc.eprint.versionFinal published versionen
dc.type.urihttp://purl.org/eprint/type/JournalArticleen
eprint.statushttp://purl.org/eprint/status/PeerRevieweden
dspace.orderedauthorsSeitel, Alexander; Walsh, Conor J.; Hanumara, Nevan C.; Shepard, Jo-Anne; Slocum, Alexander H.; Meinzer, Hans-Peter; Gupta, Rajiv; Maier-Hein, Lenaen
dc.identifier.orcidhttps://orcid.org/0000-0002-5048-4109
mit.licensePUBLISHER_POLICYen
mit.metadata.statusComplete


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record