Excitation and readout Designs for high field spectroscopic imaging
Author(s)
Lee, Joonsung
DownloadFull printable version (10.37Mb)
Other Contributors
Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.
Advisor
Elfar Adalsteinsson.
Terms of use
Metadata
Show full item recordAbstract
In this thesis we state and demonstrate solutions to three engineering problems that arise in magnetic resonance imaging RF excitation with parallel transmission (pTx) and magnetic resonance spectroscopic imaging (MRSI). Recent work in parallel RF excitation in MRI has been demonstrated to offer dramatically improved flexibility for manipulation of magnetization preparation for imaging than is feasible with conventional single-channel transmission. We address two design problems that need to be solved before this emerging technology can be deployed in the clinical and research domain of human imaging at high field. First, we demonstrate a method for rapid and robust acquisition of the non-uniform fields of RF excitation due to arrays that are commonly used in pTx at high field. Our method achieves high-fidelity single-slice excitation and reception field mapping in 20 seconds, and we propose ways to extend this to multi-slice mapping in two minutes for twenty slices. A fundamental constraint to the application of pTx is the management of the deposition of power in human tissue, quantified by the specific absorption rate (SAR). The complex behavior of the spatial distribution of SAR in transmission arrays poses problems not encountered in conventional single-channel systems, and we propose a pTx design method to incorporate local SAR constraints within computation times that accommodate pTx pulse design during MRI acquisition of human subjects. Our approach builds on recent work to capture local SAR distribution with much lower computational complexity than a brute-force evaluation, and we demonstrate that this approach can reduce peak local SAR by 20~40% for commonly applied pTx design targets. This thesis focuses on the design of excitation methods for high field system (7T parallel transmit (pTx) system) and fast readout and post-processing methods to reduce the lipid contamination to the brain. The contributions include fast B1+ mapping and pTx RF pulse design with the local SAR constraints for excitation. Regarding the readout method we developed a real time filter design, variable density spiral trajectory, and iterative non-linear reconstruction technique that reduce the lipid contamination. The proposed excitation methods were demonstrated using a 7T pTx system and the readout methods were implemented in a 3T system. Our third contribution addresses a recurring problem in MRSI of the brain, namely strong contaminating artifacts in low signal-to-noise ratio brain metabolite maps due to subcutaneous, high-concentration lipid sources. We demonstrate two methods to address this problems, one during the acquisition stage where a spatial filter is designed based on spatial priors acquired from the subject being scanned, and the second is a post-processing method that applies the brain and lipid source prior for further artifact minimization. These methods are demonstrated to achieve 20~4OdB enhancement of lipid suppression in brain MRSI of human subjects.
Description
Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2011. Cataloged from PDF version of thesis. Includes bibliographical references (p. 86-90).
Date issued
2011Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer SciencePublisher
Massachusetts Institute of Technology
Keywords
Electrical Engineering and Computer Science.