MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Graduate Theses
  • View Item
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Graduate Theses
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Methods to improve the signal quality of corrupted multi-parameter physiological signals

Author(s)
Gartheeban, Ganeshapillai
Thumbnail
DownloadFull printable version (4.055Mb)
Other Contributors
Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.
Advisor
John J. Guttag.
Terms of use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582
Metadata
Show full item record
Abstract
A modern Intensive Care Unit (ICU) has automated analysis systems that depend on continuous uninterrupted real-time monitoring of physiological signals such as Electrocardiogram (ECG), Arterial Blood Pressure (ABP), and the Photo Plethysmogram (PPG). Unfortunately, these signals are often corrupted by noise, artifacts, and missing data, which can result in a high incidence of false alarms. We present a novel approach to improve the Signal Quality of a multi-parameter physiological signal by identifying the corrupted regions in the signal, and reconstructing them using the information available in correlated signals. The method is specifically designed to preserve the clinically most signicant aspects of the signals. We use template matching to jointly segment the multi-parameter signal, morphological dissimilarity to estimate the quality of the signal segment, similarity search to nd the closest match from a database of templates, and time-warping to reconstruct the corrupted segment using the matching template. Experiments carried out on the MIT-BIH Arrhythmia Database, a multi-parameter ECG database with many clinically signicant arrhythmias, demonstrate the effectiveness of the method. Our method improved the classification accuracy of the beat type by more than 700% on the signal corrupted with white Gaussian noise, and increased the similarity to the original signal, as measured by the normalized residual distance, by more than 250%. When the method was applied to the multi-parameter physiological signal data from Cinc Challenge 2010 database at Physionet.org, our method improved the classification accuracy of beat type by more than 33 times on a signal corrupted with white Gaussian noise, and increased the similarity to the original signal by more than 280%.
Description
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2011.
 
This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.
 
Cataloged from student submitted PDF version of thesis.
 
Includes bibliographical references (p. 121-125).
 
Date issued
2011
URI
http://hdl.handle.net/1721.1/65969
Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Publisher
Massachusetts Institute of Technology
Keywords
Electrical Engineering and Computer Science.

Collections
  • Graduate Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.