MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Graduate Theses
  • View Item
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Graduate Theses
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Blind transmembrane puncture access : design and development of a novel laparoscopic trocar and blade retraction mechanism

Author(s)
Begg, Nikolai David Michael
Thumbnail
DownloadFull printable version (19.28Mb)
Alternative title
Laparoscopic trocar and blade retraction mechanism
Other Contributors
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Advisor
Alexander H. Slocum.
Terms of use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582
Metadata
Show full item record
Abstract
Blind puncture access procedures are frequent in medicine but can lead to complications due to over-puncture. When tissue membranes yield under applied stress, the device suddenly accelerates forward into the patient. Clinical background for puncture access procedures and specifically trocar insertion during laparoscopic surgery is presented. A design method is outlined and applied, with functional requirements defined and strategies and concepts detailed. The chosen mechanism concept is developed through geometric analysis. A cost-effective flexure-based mechanism is proposed as an improvement, and flexure mechanics analysis is performed. Flexure samples were manufactured and tested to validate theoretical work and fabrication technique. Prototypes were constructed, revealing the need for further design for assembly and flexure design considerations. Potential solutions are proposed and future steps outlined. The proposed device has the potential to improve safety during blind puncture access procedures by actively opposing forward acceleration of the device upon break-through thus reducing over-puncture incidents.
Description
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2011.
 
Cataloged from PDF version of thesis.
 
Includes bibliographical references (p. 77-78).
 
Date issued
2011
URI
http://hdl.handle.net/1721.1/67609
Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Publisher
Massachusetts Institute of Technology
Keywords
Mechanical Engineering.

Collections
  • Graduate Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.