MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Doctoral Theses
  • View Item
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Doctoral Theses
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Methods for functional brain imaging

Author(s)
Witzel, Thomas, Ph. D. Massachusetts Institute of Technology
Thumbnail
DownloadFull printable version (13.61Mb)
Other Contributors
Harvard University--MIT Division of Health Sciences and Technology.
Advisor
Lawrence L. Wald.
Terms of use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582
Metadata
Show full item record
Abstract
Magnetic resonance imaging (MRI) has demonstrated the potential for non-invasive mapping of structure and function (fMRI) in the human brain. In this thesis, we propose a series of methodological developments towards improved fMRI of auditory processes. First, the inefficiency of standard fMRI that acquires brain volumes one slice at a time is addressed. The proposed single-shot method is capable, for the first time, of imaging the entire brain in a single-acquisition while still maintaining adequate spatial resolution for fMRI. This method dramatically increases the temporal resolution of fMRI (20 fold) and improves sampling efficiency as well as the ability to discriminate against detrimental physiological noise. To accomplish this it exploits highly accelerated parallel imaging techniques and MRI signal detection with a large number of coil elements. We then address a major problem in the application of fMVIRI to auditory studies. In standard fMRI, loud acoustic noise is generated by the rapid switching of the gradient magnetic fields required for image encoding, which interferes with auditory stimuli and enforces inefficient and slow sampling strategies. We demonstrate a fMRI method that uses parallel imaging and redesigned gradient waveforms to both minimize and slow down the gradient switching to substantially reduce acoustic noise while still enabling rapid acquisitions for fMRI. Conventional fMRI is based on a hemodynamic response that is secondary to the underlying neuronal activation. In the final contribution of this thesis, a novel image contrast is introduced that is aimed at the direct observation of neuronal magnetic fields associated with functional activation. Early feasibility studies indicate that the imaging is sensitive to oscillating magnetic fields at amplitudes similar to those observed by magnetoencephalography.
Description
Thesis (Ph. D.)--Harvard-MIT Division of Health Sciences and Technology, 2011.
 
Cataloged from PDF version of thesis.
 
Includes bibliographical references.
 
Date issued
2011
URI
http://hdl.handle.net/1721.1/68459
Department
Harvard University--MIT Division of Health Sciences and Technology
Publisher
Massachusetts Institute of Technology
Keywords
Harvard University--MIT Division of Health Sciences and Technology.

Collections
  • Doctoral Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.