dc.description.abstractThe classical theory of boiling heat transfer based on bubble dynamics is explained and includes a full derivation of the Rohsenow boiling correlation. An alternative, more accurate correlation for determining boiling heat transfer coefficients is then presented. The theory of DC and AC electrowetting is described along with electrolyis and electric breakdown, two common problems in successfully demonstrating electrowetting. Next, the construction of a 1000V DC power supply for electrowetting experiments is outlined along with failed and successful attempts to create surfaces that exhibit electrowetting. The design and construction of an electrowetting-compatible boiling apparatus capable of delivering up to 1000W of power to a 400mm2 sample is also detailed. The power supply, surfaces, and boiler are used to determine that while electrowetting increases surface wettability it also severely decreases heat transfer, disproving the initial hypothesis. Heat transfer per unit superheat, represented by the dimensionless ratio of the Nusselt number to the Jakob number, is found to increase as a double exponential with decay constants 0.23 ± 0.21 and -14.82 ± 49.69 as a function of the dimensionless electrowetting number, a measure of electrical energy to surface energy of a liquid. Likewise, thermal resistance as a function of the electrowetting number is found to increase as a double exponential with rise constants -37.95 ± 214.4 and -0.32 ± 2.23.en_US
dc.description.statementofresponsibilityby Harrison L. Bralower.en_US
dc.format.extent47 p.en_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectMechanical Engineering.en_US
dc.titleA study of electrowetting-assisted boilingen_US
dc.typeThesisen_US
dc.description.degreeS.B.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineering
dc.identifier.oclc770905645en_US