dc.description.abstractInterdigitated electrodes are currently being used as sensing components in microfluidic lab-on-a-chip devices. The Daktari Diagnostics system uses these electrodes to measure the change in impedance of a fluid in an assay chamber. In order to improve quality assurance, a new testing method was developed and validated to characterize the sources of potential defects in the electrodes. In the new test, the electrodes are used to measure the impedance when placed in solutions of different known conductivities. The data was used to estimate the linear relationship between the inverse of the measured impedance to the solution conductivities. The repeatability tests found an average slope of 1.438x10-5 cm/characteristic length with a standard deviation of 8.52x10 -8 cm/characteristic length. It was found that the number of defective fingers or bending the electrodes significantly changes the electrode performance with a 95% confidence interval.en_US
dc.description.statementofresponsibilityby Jacklyn Holmes.en_US
dc.format.extent77 p.en_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectMechanical Engineering.en_US
dc.titleRobustness and repeatability of interdigitated electrodes on a substrate tested in an aqueous environmenten_US
dc.typeThesisen_US
dc.description.degreeM.Eng.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineering
dc.identifier.oclc775601381en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record