Show full item recordAbstract
Background
Analyze an approach to distributing transperineal prostate biopsy cores that yields data on the volume of a tumor that might be present when the biopsy is negative, and also increases detection efficiency.
Methods
Basic principles of sampling and probability theory are employed to analyze a transperineal biopsy pattern that uses evenly-spaced parallel cores in order to extract quantitative data on the volume of a small spherical tumor that could potentially be present, even though the biopsy did not detect it, i.e., negative biopsy.
Results
This approach to distributing biopsy cores provides data for the upper limit on the volume of a small, spherical tumor that might be present, and the probability of smaller volumes, when biopsies are negative and provides a quantitative basis for evaluating the effectiveness of different core spacing distances.
Conclusions
Distributing transperineal biopsy cores so they are evenly spaced provides a means to calculate the probability that a tumor of given volume could be present when the biopsy is negative, and can improve detection efficiency.
Date issued
2010-06Department
Lincoln Laboratory; Massachusetts Institute of Technology. Computer Science and Artificial Intelligence LaboratoryJournal
Theoretical Biology and Medical Modelling
Publisher
BioMed Central Ltd.
Citation
Kepner, Gordon R., and Jeremy V. Kepner. “Transperineal Prostate Biopsy: Analysis of a Uniform Core Sampling Pattern That Yields Data on Tumor Volume Limits in Negative Biopsies.” Theoretical Biology and Medical Modelling 7.23 (2010): 1-13.
Version: Final published version
ISSN
1742-4682