MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Graduate Theses
  • View Item
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Graduate Theses
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Residential building energy analysis : development and uncertainty assessment of a simplified model

Author(s)
Spindler, Henry C. (Henry Carlton), 1970-
Thumbnail
DownloadFull printable version (14.95Mb)
Alternative title
Development and uncertainty assessment of a simplified model
Other Contributors
Massachusetts Institute of Technology. Dept. of Architecture.
Advisor
Leon R. Glicksman.
Terms of use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582
Metadata
Show full item record
Abstract
Effective design of energy-efficient buildings requires attention to energy issues during the preliminary stages of design. To aid in the early consideration of a building's future energy usage, a simplified building energy analysis model was developed. Using this model, a new computer program was written in C/C++ to calculate annual heat and cooling loads for residential buildings and to provide information about the relative importance of load contributions from the different building components. Estimates were made regarding the uncertainties of parameter inputs to the model, such as material properties, heat transfer coefficients and infiltration rates. The new computer program was used to determine the sensitivity of annual heat and cooling loads to model input uncertainties. From the results of these sensitivity studies, it was estimated that the overall uncertainties in the annual sensible heat and cooling load predictions amount to approximately ±30% and ±40%, respectively, for two buildings studied in Boston, Massachusetts. Further model simplification techniques were implemented that reduced annual load calculation times on a 180 MHz computer to about 8 and 12 seconds for a lightweight and massive building, respectively. The error introduced by these simplifications was approximately 4% and 10% for the annual sensible heat and cooling loads, well below the overall uncertainties in the load predictions. Comparison studies were performed with this new computer program and Energy-10. Overall, good agreement between the programs' annual load predictions was found.
Description
Thesis (M.S.)--Massachusetts Institute of Technology, Dept. of Architecture, 1998.
 
Includes bibliographical references (p. 163-165).
 
Date issued
1998
URI
http://hdl.handle.net/1721.1/70305
Department
Massachusetts Institute of Technology. Department of Architecture
Publisher
Massachusetts Institute of Technology
Keywords
Architecture.

Collections
  • Graduate Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.