Off-peak cooling using phase change material

Author(s)
Benton, Charles Crisp
Thumbnail
DownloadFull printable version (8.347Mb)
Other Contributors
Massachusetts Institute of Technology. Dept. of Architecture.
Advisor
Timothy E. Johnson.
Terms of use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582
Metadata
Show full item record
Abstract
The electric utilities in the United States are faced with continued rapid growth in electrical demand. The traditional response to growth in demand has been the expansion of generating capacity. However, economic, environmental, and scheduling constraints will combine to make adequate expansion difficult, if not impossible, in the 1980's. This thesis examines load management as an alternative to the proliferation of generating plants. This path is illustrated by the development of an air conditioning system designed to displace power consumption in commercial buildings from peak to off-peak periods. The urban domestic utilities face their peak loads during the summer air conditioning season. The displacement of daytime air conditioning will therefore reduce the utilities' annual peak load. The proposed air conditioning system uses off-peak power, and conventional mechanical equipment, to recharge a thermal energy storage system. The thermal storage medium is a sodium sulfate-based phase change material (PCM) enclosed in small thin bags. These bags are distributed throughout the ceiling plane of the building; supported by special ceiling tiles. At night, the PCM is charged by chilling the plenum space; during the day, the PCM, in direct contact with the occupied space, removes sensible heat gains by melting. System components are described by their programmatic requirements. The performance of the proposed off-peak cooling system was simulated under a variety of conditions involving interior zone commercial office spaces. It was found, using thermal comfort criteria, that the system performed well using a PCM set point temperature of 67°F. Under the operating parameters established, the simulations indicated that the energy flow rates were adequate for successful system performance. Finally, it was determined that the system can provide immediate savings through customer demand leveling and increased chiller efficiency. However, the major potential for savings will relate to anticipated utility incentives for off-peak electrical use.
Description
Thesis (M. Arch.)--Massachusetts Institute of Technology, Dept. of Architecture, 1979.
 
MICROFICHE COPY AVAILABLE IN ARCHIVES AND ROTCH.
 
Includes bibliographical references.
 
Date issued
1979
URI
http://hdl.handle.net/1721.1/71312
Department
Massachusetts Institute of Technology. Department of Architecture
Publisher
Massachusetts Institute of Technology
Keywords
Architecture.

Collections
  • Graduate Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.