Show simple item record

dc.contributor.advisorSang-Gook Kim.en_US
dc.contributor.authorSmyth, Katherine Marieen_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Mechanical Engineering.en_US
dc.date.accessioned2012-11-19T19:20:28Z
dc.date.available2012-11-19T19:20:28Z
dc.date.copyright2012en_US
dc.date.issued2012en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/74942
dc.descriptionThesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2012.en_US
dc.descriptionCataloged from PDF version of thesis.en_US
dc.descriptionIncludes bibliographical references (p. 149-156).en_US
dc.description.abstractThe design and modelling framework for a piezoelectric micromachined ultrasonic transducer (PMUT) based on the piezoelectric thin film deposition of lead zirconate titanate (PZT) is defined. Through high frequency vibration (1-16MHz) of a thin plate, the PMUT transmits and receives pressure pulses to construct medical ultrasound images as an alternative to bulk piezoelectric transducers currently in use. Existing transducers are difficult to fabricate and lack the small scale necessary for small form factor, high resolution 2D imaging arrays. From acoustic priniciples, the potential PMUT acoustic pressure output is determined and compared to a radiating rigid piston model. Acoustic pressure is shown to scale with the volumetric displacement rate, which is related to the plate deflection. A Green's function approach is then used to explicitly solve for the plate deflection of a bimorph and unimorph PMUT with an arbitrary number of circular or ring electrodes. The resulting solution is much simpler and more flexible than previously published solution techniques enabling the optimization of electrode configuration for large deflection and acoustic pressure. Additionally, the contribution of residual stress is examined; particularly its effects on bandwidth, sensitivity, and resonant frequency and an appropriate electrode coverage of the PMUT plate is suggested. Based on modelling, an initial PMUT design is proposed and is currently being fabricated.en_US
dc.description.statementofresponsibilityby Katherine Marie Smyth.en_US
dc.format.extent156 p.en_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectMechanical Engineering.en_US
dc.titleDesign and modeling of a PZT thin film based piezoelectric micromachined ultrasonic transducer (PMUT)en_US
dc.title.alternativeDesign and modeling of a lead zirconate titanate thin film based piezoelectric micromachined ultrasonic transducer (PMUT)en_US
dc.typeThesisen_US
dc.description.degreeS.M.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineering
dc.identifier.oclc815969104en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record