MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Graduate Theses
  • View Item
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Graduate Theses
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

A Lorentz-force actuated needle-free intraocular injection device

Author(s)
White, James E
Thumbnail
DownloadFull printable version (10.86Mb)
Other Contributors
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Advisor
Ian W. Hunter.
Terms of use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582
Metadata
Show full item record
Abstract
Intravitreal injection is a common treatment in ophthalmology, but it can lead to considerable patient anxiety and numerous complications. Lorentz-force actuated needle-free jet injection has been shown to successfully deliver fluid to various layers of skin, and, by its nature, may reduce intravitreal injection anxiety and complications. The challenges of adapting current Lorentz-force actuated needle-free jet injection technology to intravitreal injection were investigated using a previously developed jet injection system. Two iterations of an intravitreal injection-specific control scheme were designed, implemented, and tested. Several tools were developed in tandem with the research, including intravitreal injection 3D reconstruction software, actuator-jet transfer function generation software, and bench-top eye injection staging equipment. From injection trials into ex vivo rabbit eyes, we find that needle-free jet injection can be used for intravitreal drug delivery. The new system is capable of delivering 40 [mu]L of fluid to the posterior vitreous humor, with an injection duration less than 100 ms and scleral entry site less than 350 [mu]m in diameter. A relationship has been developed between injection parameters and eye damage metrics that can be used for future parameter optimization, minimizing damage to the eye.
Description
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2012.
 
Cataloged from PDF version of thesis.
 
Includes bibliographical references (p. 73-77).
 
Date issued
2012
URI
http://hdl.handle.net/1721.1/74949
Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Publisher
Massachusetts Institute of Technology
Keywords
Mechanical Engineering.

Collections
  • Graduate Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.