MIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Graduate Theses
  • View Item
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Graduate Theses
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Effects of a powered ankle prosthesis on shock absorption and residual limb/socket interface pressure

Author(s)
Hill, David Allen, Ph. D. Massachusetts Institute of Technology
Thumbnail
DownloadFull printable version (9.998Mb)
Other Contributors
Massachusetts Institute of Technology. Dept. of Architecture. Program in Media Arts and Sciences.
Advisor
Hugh Herr.
Terms of use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582
Metadata
Show full item record
Abstract
Lower-extremity amputees face potentially serious post-operative complications, including increased risk of further amputations, excessive stress on both limbs, and discomfort at the stump/socket interface. State of the art; passive prostheses have improved many negative consequences associated with lower-limb loss, but we believe the limit of uninformed elastic prostheses has been reached. Further strides require a more biomimetic approach. Through integration of "smart" technology (sensors and actuators), a new phase of bionic lower-limb prostheses is upon us, which enables prosthetic devices to more closely mimic biological behavior by generating human-like responses and power outputs. The closer we come to natural biology, gait abnormalities in amputees will decline. This project compares the first bionic ankle prosthesis to commonly used passive prostheses to determine how more biomimetic adaptability and work generation in the prosthetic joint affects discomfort and joint stress. We have put forth several metrics to describe discomfort (elements of shock absorption, pressure distribution, etc.) and will conduct level-ground walking tests with three unilateral amputee subjects using both passive and power devices. We hope to make a case for the pursuit of more biomimetic designs for rehabilitative devices, by showing a positive effect on "comfort" and a restoration of normal gait dynamics when using a bionic ankle prosthesis.
Description
Thesis (S.M.)--Massachusetts Institute of Technology, School of Architecture and Planning, Program in Media Arts and Sciences, 2012.
 
Cataloged from PDF version of thesis.
 
Includes bibliographical references (p. 83-86).
 
Date issued
2012
URI
http://hdl.handle.net/1721.1/76517
Department
Program in Media Arts and Sciences (Massachusetts Institute of Technology)
Publisher
Massachusetts Institute of Technology
Keywords
Architecture. Program in Media Arts and Sciences.

Collections
  • Graduate Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.