An analysis of the impact of datacenter temperature on energy efficiency

Author(s)
Lee, Heechang
Thumbnail
DownloadFull printable version (6.621Mb)
Other Contributors
System Design and Management Fellows Program.
Advisor
Gregory J. McRae.
Terms of use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582
Metadata
Show full item record
Abstract
The optimal air temperature for datacenters is one of ways to improve energy efficiency of datacenter cooling systems. Many datacenter owners have been interested in raising the room temperature as a quick and simple method to increase energy efficiency. The purpose of this paper is both to provide recommendations on maximizing the energy efficiency of datacenters by optimizing datacenter temperature setpoint, and to understand the drivers of datacenter costs. This optimization and the potential energy savings used in cooling system can drive higher energy use in IT equipment and may not be a good trade off. For this reason, this paper provided a detailed look at the overall effect on energy of temperature changes in order to figure out the optimal datacenter temperature setpoint. Since this optimal temperature range varies by equipment and other factors in the datacenter, each datacenter should identify its appropriate temperature based on the optimization calculation in this paper. Sensitivity analysis is used to identify the drivers of the cost of ownership in a datacenter and to identify opportunities for datacenter efficiency improvement. The model is also used to evaluate potential datacenter efficiency.
Description
Thesis (S.M. in Engineering and Management)--Massachusetts Institute of Technology, Engineering Systems Division, System Design and Management Program; in conjunction with the SDM Fellows Program, 2012.
 
Cataloged from PDF version of thesis.
 
Includes bibliographical references (p. 65-66).
 
Date issued
2012
URI
http://hdl.handle.net/1721.1/76590
Department
System Design and Management Program.; Massachusetts Institute of Technology. Engineering Systems Division
Publisher
Massachusetts Institute of Technology
Keywords
Engineering Systems Division., System Design and Management Program., System Design and Management Fellows Program.

Collections
  • Graduate Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.