Show simple item record

dc.contributor.advisorJacopo Buongiorno and Thomas McKrell.en_US
dc.contributor.authorSugrue, Rosemary Men_US
dc.contributor.otherMassachusetts Institute of Technology. Dept. of Nuclear Science and Engineering.en_US
dc.date.accessioned2013-02-14T15:34:00Z
dc.date.available2013-02-14T15:34:00Z
dc.date.copyright2012en_US
dc.date.issued2012en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/76974
dc.descriptionThesis (S.M. and S.B.)--Massachusetts Institute of Technology, Dept. of Nuclear Science and Engineering, 2012.en_US
dc.descriptionCataloged from PDF version of thesis.en_US
dc.descriptionIncludes bibliographical references (p. 119-122).en_US
dc.description.abstractThe effects of orientation angle, subcooling, heat flux, mass flux, and pressure on bubble growth and detachment in subcooled flow boiling were studied using a high-speed video camera in conjunction with a two-phase flow loop that can accommodate a wide range of flow conditions. Specifically, orientation angles of 0' (downward-facing horizontal), 30°, 45°, 60°, and 90° (vertical); mass flux values of 250, 300, 350, and 400 kg/m²s, with corresponding Froude numbers in the range of 0.42 to 1.06; pressures of 101 (atmospheric), 202, and 505 kPa; two values of subcooling (10°C to 20°C); and two heat fluxes (0.05 to 0.10 MW/m²) were explored. The combination of the test section design, high-speed video camera, and LED lighting results in high accuracy (order of 20 microns) in the determination of bubble departure diameter. The data indicate that bubble departure diameter increases with increasing heat flux, decreasing mass flux, decreasing levels of subcooling, and decreasing pressure. Also, bubble departure diameter increases with decreasing orientation angle, i.e. the largest bubbles are found to detach from a downward-facing horizontal surface. The mechanistic bubble departure model of Klausner et al. and its recent modification by Yun et al. were found to correctly predict all the observed parametric trends, but with large average errors and standard deviation: 35.7+/-24.3% for Klausner's and 16.6±11.6% for Yun's. Since the cube of the bubble departure diameter is used in subcooled flow boiling heat transfer models, such large errors are clearly unacceptable, and underscore the need for more accurate bubble departure diameter models to be used in CFD.en_US
dc.description.statementofresponsibilityby Rosemary M. Sugrue.en_US
dc.format.extent122 p.en_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectNuclear Science and Engineering.en_US
dc.titleThe effects of orientation angle, subcooling, heat flux, mass flux, and pressure on bubble growth and detachment in subcooled flow boilingen_US
dc.typeThesisen_US
dc.description.degreeS.M.and S.B.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Nuclear Science and Engineering
dc.identifier.oclc824780699en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)