Show simple item record

dc.contributor.advisorJoel Voldman.en_US
dc.contributor.authorSu, Hao-Weien_US
dc.contributor.otherMassachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.en_US
dc.date.accessioned2013-04-12T19:27:18Z
dc.date.available2013-04-12T19:27:18Z
dc.date.copyright2012en_US
dc.date.issued2012en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/78471
dc.descriptionThesis (S.M.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2012.en_US
dc.descriptionCataloged from PDF version of thesis.en_US
dc.descriptionIncludes bibliographical references (p. 86-90).en_US
dc.description.abstractDielectrophoresis (DEP), a cell separation technique based on the dielectric properties, has significantly advanced biomedical research in diverse applications ranging from blood stem cells purification to cancer cells isolation from heterogeneous populations. The ability to accurately measure the dielectric properties of individual cells is not only critical for effective sorting applications, but is also advantageous for enhancing the current knowledge of cell biology. This thesis proposes a novel method: the n-DEP spring, which applies an electrical field gradient upon continuously flowing cells to distinguish them based on their individual DEP properties. Specifically, the method uses the equilibrium position originating from the force balance between hydrodynamic and DEP forces to infer the cellular dielectric properties. For thorough DEP characterization, changing different conditions of cells is an essential but time-consuming process which usually takes hours to days. Especially for DEP characterization of time-sensitive events, such as neutrophil activation or cell apoptosis, short characterization time is required. This thesis describes the automation of the fluidic, optics, and electronics components of the DEP characterization system, which shortens the characterization time within an hour. We first demonstrated the automated DEP characterization of a mammalian cell type in thirty-nine conditions within an hour. Subsequently, we characterized the neutrophils with different activation states and successfully found out the right conditions to discriminate the activated neutrophils and non-activated neutrophils. With this system and method, we now have the potential to rapidly screen through a variety of system parameters, and optimize conditions for effective cell sorting.en_US
dc.description.statementofresponsibilityby Hao-Wei Su.en_US
dc.format.extent90 p.en_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectElectrical Engineering and Computer Science.en_US
dc.titleThe development of an automated system for electrical characterization of cells using a novel force balance methoden_US
dc.typeThesisen_US
dc.description.degreeS.M.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
dc.identifier.oclc834089420en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record